Jupiter Crosspoint Bus Controller Configuration
If the setting for this switch is On:
• The Controller in CMS1 will take control as Master, or
• If the Controller in CMS1 fails,
the Controller module in CMS2 will
take over, or
• If the Controller in CMS1 is reset, the Contr
oller module in CMS2
will take over until the Controller in CMS1 reboots at which time
the Controller in CMS1 will take control, or
• If there is only one Controller module and it is in CMS2,
it will be
Master, or
• If there is one Controller module in CMS2, and a second Controller
mod
ule is seated and booted in CMS1, the Controller module in
CMS1 will take control.
If the setting for this switch is Off:
• When there are two Controller mod
ules, whichever one boots the
fastest will be the Master, or
• If there is only one Controller modul
e and it is in either Controller
module slot it will be the Master.
6. Set Level and Options for each slot.
Banks S2, S3, S4, S5, S7, S8, S9, and S10 ar
e used to assign Levels and
Options to the module slots. DIP Switch number 8 is not used on banks
S4, S7, or S8. Table 47 shows which banks and setting types are used for
each slot.
Table 47. DIP Switch Bank and Module Slot Number
Module Slot # DIP Switch Bank Setting Type
1
S2 Level
S3 Options
2
S4 Level
S5 Options
3
S7 Level
S8 Options
4
S9 Level
S10 Options
Table 48 shows the common default level settings used by matrices in
the Jupiter Control System. You can set any of 127 possible levels, see
Appendix B-Reference Tables for the complete set. The common levels
shown are the ones supported by Concerto.