Instruction manual

Concerto — Instruction Manual 129
Field Replaceable Units
Port Modules
The Port module was modified so that the interface between the module
and the Port Backplane (9 pin D) adheres to the industry standard. This
modification (FMN 075-0731-00) applies to Port modules with part
numbers of 671-6374-00D or earlier. If your Port modules need the modifi-
cation, contact Grass Valley Customer Service. I
f your Port modules are
671-6374-00E or newer, your Port modules do not need to be modified.
Note Port modules that are used as TimeCode do not require this modification.
Figure 81. Part Number Location
GRASS VALLEY GROUP
PORT 32X32 CRS2001
671-6374 –
MADE IN U.S.A.
If the number in the box is:
00A to 00D, this is an older
board. It needs to be modified.
8138_04_99r0
Audio and SD Video Module Modifications
Field Modification Note 075-0705-00 corrects a problem on several Con-
certo modules. Crosspoints will not switch
if one-shots time out during a
slow sync. This applies only to Concerto modules identified in Table 52. If
your modules are at the
New Letter Version shown in the table, or newer, then
you do not need this modification. If your modules need the modification,
contact Grass Valley Customer Service.
Table 52. Assembly Part Numbers and Letter Versions
Module Part Number Dash Number
Current Letter
Ve
rsion
New Letter
Version
Analog Video 671-6369
-00 A1 to C1 D1
-01 A1 B1
-50 A1 to C1 D1
-51 A1 B1
Analog Audio 671-6370
-01 A1 B1
-25 A1 B1
-50 A1 B1
Digital Audio 671-6371 -00‘ A1 to H1 J1