Control System Configuration
The Concerto can connect to different control systems using either Cros-
spoint Bus or Ethernet buses. Control using a Cr
osspoint Bus interface
requires DIP Switch and Rotary Switch settings. Control using an Ethernet
interface requires IP address configuration.
This section covers the IP settings, swi
tch settings, and specific configura-
tion items that Concerto requires to be contr
olled. General configuration
areas that apply to all matrices connected to a control system are covered in
the Instruction Manuals for the control system.
Controllers
All of the Concerto Controllers can communicate via Ethernet. The CRS-
MC-C2 module communicates via Ethernet or Crosspoint Bus based on the
configuration of the Control
MODE/IN SEL DIP Switch.
Control Mode/In Sel Setting
8138_03_97r0
18765432
ON
18765432
ON
18765432
ON
18765432
ON
18765432
ON
18765432
ON
18765432
ON
18765432
ON
18765432
ON
PWR
OK
DONEACT
GND
+5V
ERROR
TC2
PRES
BUSY
48K
PRES
LINK
SYNC
ERR
RECV
VI 2
PRES
XMIT
VI 1
PRES
CLEAR MEM
RESET
TX
RXFAST COL TC1
PRES
+2.5V
+3.3V
A_LEVEL
B_LEVEL
A_OPTIONS
C_LEVEL
D_LEVEL
B_OPTIONS
C_OPTIONS
D_OPTIONS
MODE/IN
SEL
S11
S12
S13
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
MATRIX MAP
CONFIG
18765432
ON
CLEAR MEM
MODE/IN
SEL
S11
On the CRS-MC-C2 Controller module, DIP Switch bank S11 (MODE/IN SEL)
determines the control system interface. If this bank is configured for
Et
hernet (field or frame switching rate) control, then all of the other DIP
Switches and Rotary Switches are bypassed and the controller uses
Ethernet to communicate. If this bank is set for Crosspoint Bus (field or
frame switching rate) control, then all of the other DIP Switches and Rotary
Switches are used to configure the Concerto matrix.
Table 41. Bank S11 DIP Switch Settings for Control Mode
Control Mode In Control System Switching Rate
Switch Settings
a
Switches #5 through #8 are for Factory Use and must be set to OFF for normal operation.
a
Crosspoint Bus
Jupiter
Field OFF OFF OFF ON
Frame ON OFF OFF ON
Ethernet SMS 7000 Field OFF OFF OFF OFF
Encore Frame ON OFF OFF OFF
#1 #2 #3 #4