Instruction manual
106 JUPITER CM-4400 Control Module Installation and Operating Manual
Section 4 — Jupiter Network Suite Control Console
Clearing Persistent Memory (PMEM)
The Persistent Memory (PMEM) is cleared by selecting the Clear PMEM
button on the Board Info /Control tab of the Control Center Application.
For more information about the Control Center, see Jupiter Network Suite
Control Console on
page 97.
When the PMEM is cleared, all switcher status
will be lost (no switches will
take place). The switcher status will not be restored until the switches are
manually re-taken. In addition, the links to the control panels will have to
be re-established.
Follow these steps to clear the Persistent Memory (PMEM):
1. Start the Control Center (Go to Start > Programs > Jupiter Network
Suite > JNS Applications > Control Center).
2. Click the Board Info /Control tab (Figure70).
Figure 70. The Configuration Tab of the Control Center Application
3. Select the board that you want to clear.
4. Click the Clear PMEM button.
After the PMEM has been cleared, the boards will automatically reset.