134 JUPITER CM-4400 Control Module Installation and Operating Manual
Section 5 — The Configurator Application
2. Select the Compile option from the Tools menu (Tools> Compile).
When the compiler is finished, the number of compiler errors (if any)
will be reported.
If a compiler error is reported, the error must be corrected and the set re-
compiled. Click the Print command box to print the error messages.
A new set must compile without errors
and be explicitly selected for down-
loading by the Control Center software
before it can go online. Do not
worry about an error corrupting the active set-even if the active set has the
same name as the one you’re working on.
3. Click the Close button.
4. Use the JNS Console to start the Jupiter Network Suite’s (JNS) Control
Center application (Figure93). The Control Center application will
then open.
The Bootp Server program will also be started automatically in the
backgr
ound.
5. Select the new set in the text window.
6. Select the Select and Reboot radio button if it not already selected.
Figure 93. The Jupiter Control Center
7. Click the Activate button to initiate the download.
CAUTION Once the activate/reboot command has been issued, do not interrupt the
process until the reboot is complete. Interruptions such as sending a new
command, turning off power, or disconnecting cables will have unpredictable
consequences. With a CM-4400, such consequences can include corruption
of data stored in flash memory and on the CM hard drive.