Instruction manual
JUPITER CM-4400 Control Module Installation and Operating Manual 135
Configuration Set Management
After a few seconds, the LEDs on the controller boards will turn red
momentarily and the message “Device not connected” or “Startup” will
appear on the system control panels. When the download is complete, the
LEDs should be green and the panels returned to their previous status dis-
play. A complete set change can take several seconds or multiple minutes.
The
Download status can also be determined using the Control Center’s
Board Status tab.
Figure 94. The Jupiter Control Center’s Board Status Tab
Note Special procedures are available for CM-4400 systems to minimize system
downtime during set activation. See Download Now / Reboot Later below.
All control panels should now be operational. For operating instructions,
see the appropriate user manual. ( JEP-100 Jupiter / Encore Control Panel
v1.2.0 Installation and Operating Manual, Jupiter Control System L-S and LCD
Series Control Panels Installation and Operating Manual.)
Download Now / Reboot Later (“Pending Reboot”)
Please refer to Figure 95 on page 136.
In order to minimize system downtime due to
changes in configuration
and application code and to provide the operator the ability to coordinate
the time that the system is unavailable, modifications were made to
Windows and the CM-4400 embedded code resulting in a different config-
uration set and code activation procedure compared to previous Jupiter
re
leases.
With the CM-4400, it is possible to download a configuration set and a copy
of
the application code without actually placing them in operation; during
this “Pending Reboot” state the CM-4400 continues to operate without
interruption using the previously executing application code and configu-
ration. The new set and application code will only be placed in use after the
CM-4400
has been rebooted.