Instruction manual
JUPITER CM-4400 Control Module Installation and Operating Manual 137
Configuration Set Management
Figure 96. The Jupiter Control Center
With the CM-4400, choosing the Select and Reboot radio button will not cause 
the CM-4400to reboot. Reboot of the processor should be accomplished 
through the use of the 
Reboot button on the Board Info/Control menu, as 
described below.
In order to download new application code, you must select a configura-
tion set for Activation even if it 
has the same name as the set that is shown 
as Current. This action causes the system to recalculate the checksum of 
system files allowing the processor to determine the need to download/
update files.
If the configuration set selected for activation and
 the Current set have 
identical content, the command to Activate (download) will be recognized 
to be un-needed. If application code has changed, the processor will down-
load the set as a result of these actions.
When a Configuration set is activated, the CM-4400 will download the con-
figuration and the application code as a 
background task. 
Note This newly activated configuration and code is not placed in operation on the 
CM-4400 until a reboot of the processor is performed.
4. Click the Board Info/Control tab to monitor the status of the CM-4400 
processors.
The system will compare the
 configuration set that was downloaded with 
the configuration set that is currently in operation. If they are different, the 
cell will be red and the phrase Pending Reboot will appear in the Configu-
ration column. This Pending Reboot c
ondition is shown in Figure97. 