Instruction manual
JUPITER CM-4400 Control Module Installation and Operating Manual 139
Configuration Set Management
5. Once the Configuration or Code is successfully downloaded, which 
will be indicated by a green cell and the phrase Pending Reboot, you 
can, at a convenient time, select the processors either individually or by 
clicking the 
Select All button and then click the Reboot button to reboot 
the processor (The 
Clear PMEM button may be used to reboot the 
processor). The result is shown in Figure99.
Figure 99. The Jupiter Control Center-Results of a Reboot
The phrase, “OK” means that the set/code that is running is the same as the 
set/code that is on the file server.
Note In systems with more than one controller board it is a good practice to com-
plete the Pending Reboot process as soon as practical.
Mismatch Indicator
Please refer to Figure97 and Figure98.
The Mismatch indicator will show when the s
et/code in the file server is 
different than the set/code that is executing in a CM-4400. It is possible for 
the set/code is downloaded (or selected for download) to be different than 
the software that is actually in operation. For example, the Pending Reboot 
condition, where a set and application are downloaded for Reboot at a later 
time. The Mismatch indicator will also appear if there is a controller board 
changeover, a selective download, or a break in the network. 
It is normal for the Mismatch indicator to appear w
hile files are being 
downloaded from the file server to a controller board. The progress and 
state of the download can be observed by clicking on the TFTP Status tab 
in the Control Center.