Instruction manual
150 JUPITER CM-4400 Control Module Installation and Operating Manual
Section 5 — The Configurator Application
Entering Descriptions of Controller Boards
Before you begin:
• In most cases, you will want to modify
the set that is currently active;
Grass Valley recommends that you copy the active set and then select
the copy for editing. For more information, please see Copying a Config-
uration Set for Editing on page 130.
• Check to see that the Configuration set you selected is the set that you
want to change. The name of the Configuration set will be in the Title
bar at the top of the Jupiter Configurator window.
Follow these steps to enter a description for a controller board:
1. Select the Network Description option from the Jupiter menu (Jupiter >
Network Description). This will open a table that is similar to what is
shown in Figure 107 on page 149.
2. Double-click the first Board Name field.
3. Enter the preferred name for the board. This name can be up to eight
characters in length.
4. Press the Tab key on your keyboard to advance to the board Type box.
A pop-up menu will list the possible board types. Select a type based
on hardware and application:
5. Select the Address box and enter the Ethernet hardware address for the
board.
• For the CM-4400 and other system controllers, the address is shown
on the back panel.
• Use the Backspace key to erase.
Table 5. Type Field Options
Board Application Entry Type
CM-4400 AccuSwitch processor AS
CM-4000 AccuSwitch processor AS
CM-4000 Jupiter XPress processor SB
Saturn AAP Analog audio processor AA
Saturn AVP Analog video processor AV
Saturn CP Control panel CP
Saturn DAP Digital audio processor DA
Saturn DVP Digital video processor DV
Saturn HDVP High definition video HD
PC Software control panel suite PC