Instruction manual
JUPITER CM-4400 Control Module Installation and Operating Manual 153
Serial Protocol Table
Note On the top of the Jupiter Configurator window on the title bar, you will see the
name of the Configuration set. Check to see whether the configuration set
that you want to change is selected.
Follow these steps to enter or modify the Serial Protocol table:
1. Select the Serial Protocol option from the Jupiter menu (Jupiter > Serial
Protocol). This will open a table similar to that shown in Figure109. The
Board names should already be present (they were established using
the Network Description Table).
2. Click the appropriate protocol box. A pull-down menu will list the
possible protocol types. Click on the preferred type.
3. Continue the process for the baud rate fields. Baud rates will be selected
automatically for some protocols.
4. Save your changes.
5. Compile and activate the Configuration set. (See Validating, Compiling,
and Activating (Downloading) a Configuration Set on page 133 if you need
more information.)
Serial Protocol Selection Options
The possible selections are as follows (NA = not available, Opt =
optional, Std = default):
Note Protocol for automation systems varies. Refer to additional protocol docu-
mentation supplied with the automation system.
Table 6. Serial Protocol Selections
Device Type Protocol 1200 2400 4800 9600 19200 38400 115000
AlpahImage ALP NA NA Opt Opt Opt Std NA
ASCII ASC Opt Opt Opt Std Opt Opt Note 1
CM Es-Tributary CET Opt Opt Opt Opt Opt Std NA
Datatek DTK NA NA NA NA NA Std NA
Es-Control EXC NA NA NA NA NA Std NA
ES-Control Panel ESCP Opt Opt Opt Opt Opt Opt Std
ES Switch ESW Opt Opt Opt Opt Opt Std
GVG Native Protocol GNP Opt Opt Opt Opt Opt Opt Opt
GVG Horizon HRZ NA NA NA NA NA Std NA
Nexus Star NST NA NA NA NA NA Std NA
NVision NV NA NA NA NA NA Std NA
Nexus NZS NA NA NA NA NA Std NA
Triton TRI NA NA NA NA Std NA NA
Utah 1200 Baud U12 Std NA NA NA NA NA NA
Utah 9600 Baud U96 NA NA NA Std NA Std NA