Instruction manual

186 JUPITER CM-4400 Control Module Installation and Operating Manual
Section 5 — The Configurator Application
The Control Panel Category Set
The CP Category Set table allows the category names to be customized.
(Categories are classes of inputs/outputs, such as “CAM.”) This table is the
source of the name that appears in the display window when a category
key is pressed.
A CP Category Set is normally assigned t
o a CP Input Set and to a CP
Output Set when those sets are first created. However, this assignment can
be changed later if preferred. The CP Input and Output Sets are in turn
assigned to specific control panels on the MPK Devices table.
Each Category Set can contain up to 98 category mnemonic
s; if less than 20
categories are entered, the remaining category keys will be inoperable.
Defining Categories
For steps activating the Control Panel Set dialog, see Creating a CP Set on
page 171.
Figure 133. Control Panel Sets - New Sequence
Follow these steps to define a category:
1. Select the Category radio button in the lower-left of the Type of Set area
of the dialog. The names of any previously created Categories set will
then appear in the Categories Sets: window.
2. Enter a name for the category set in the Name field.
3. Select the appropriate CP type from the CP Type drop-down list.
4. Click the Apply button the new sequence will appear in the Sequence
Sets window.