Instruction manual

206 JUPITER CM-4400 Control Module Installation and Operating Manual
Section 5 — The Configurator Application
address of the host CM-4400 (the IP address can be determined using
the JNS Board Status menu).
RTC Host / Address: Create the host name and enter the IP address if a Real
Time Clock host computer will be used to supply time information.
Time Zone Name: Create a description of the local time zone. The field will
accept any text that is a maximum of eight characters.
Offset from GMT: (required) Enter the hours and minutes offset from the
Greenwich Mean Time (Coordinated Universal Time or “UTC”).
Time zones west of Greenwich require a minus entry; time zones east of
G
reenwich require a plus entry. For example, New York City would be
-05:00. The offset from GMT must be supplied so that the correct time is
displayed. Time in the CM-4400 is always kept in UTC2 internally.
When time is displayed, it is shifted according the offset for the local
time zone.
DST Start Month / Day / Hour: (required) Enter the Daylight Savings start
date and time in the respective fields.
DST End Month / Day / Hour: (required) Enter the Daylight Savings stop date
and time in the respective fields.
Note If you don’t wish to use Daylight Savings, enter the same month, date, and
time for Start and Stop.
Using the Numeric Sets for Quick Switcher Checkout
The factory-supplied numeric configuration sets can be used to set up and
operate the routing switcher in the minimum possible time. The
“NUMERIC” set provides for a switcher with up to 256 inputs, 256 outputs,
and four levels; the “NUM-64” set provides for 64 inputs and outputs; and
the “NUM-128” set provides for 128 inputs/outputs.
The numeric sets are complete and ready to download, except for entry of
at least one CM-4400 Contr
ol Chassis address, entry of the actual switcher
Physical Levels and Driver types, and one switcher control panel address.
Use the “File > Open” menu to select one of the Numeric sets and make a
copy (See Copying a Configurati
on Set for Editing on page 130.) Select Jupiter
> Network Description table and change
the CM-4400 address to match
those in your system. The actual switcher Physical Levels and Driver types
are entered on the Switcher Description Table on page 156. The control panel
address must be entered on the MPK Devices Description table (page 191).
The set can then be compiled and activated
as described in Validating, Com-
piling, and Activating (Downloading) a Configuration
Set on page 133.