JUPITER CM-4400 Control Module Installation and Operating Manual 211
Remote System Routing
Remote System Routing Characteristics
Remote System routing has several notable characteristics:
• Each Jupiter system can include one or m
ore matrix routers.
• Each Jupiter system must include a Jupiter file server.
• Any control panel can control any matrix router.
• The status of all of the matrix routers can be shown on all control
panels.
• Each Jupiter system must include at least one AccuSwitch CM−4000.
• AccuSwitch does not support MPK control panels. If MPK devices are
required, they must be connected to a separate CM-4000 running
Jupiter XPress or a VM−3000 running Jupiter Plus.
• Multiple Jupiter systems can be connected through IP routers.
• Each system must be configured to recognize the other(s). This must be
done using each system’s file server (as described below).