CM-4400 System Codes
65 Serial Processor: Primary directory
copied from the secondary direc-
tory.
When the primary directory was checked it indicated a
data corruption problem and was replaced by the sec-
ondary directory copy because its contents checked
OK.
66 Serial Processor: Update Flash
Directory write Dir failed to write
directory
The flash file system attempted to update the directory
in memory but the write to flash failed for the primary
directory copy 1 or secondary directory copy 2.
67 Serial Processor: Serial Port Error A separate thread is watching all the serial port metrics
error counts.
This event is logged when any ports line, protocol, or
timeout error count exceeds zero or its previously
logged value.
68 Serial Processor: Frame processor
failed to ACK serial message before
timeout
When a message comes from a serial port protocol it
is transferred from the serial processor to the frame
processor to be processed by the system.
The protocol expects to receive either a positive or
negative acknowledge. If that response is not received
within the specified timeout period this event is
logged.
Table 23. Messages 69 to 70
Message Number Short Message Detailed Description
69 Serial Processor Undefined: %s Undefined serial processor log event.
See message string.
6A Cannot run unit test for %s with
production code
You cannot run unit tests when the code is compiled
for production.
6B Could not create unit test task for
%s
Failed to create the unit test task.
6C Could not create unit test cleanup
task for %s
Failed to create the unit test cleanup task.
6D Unable to initialize the bootp infor-
mation. Activate a valid configura-
tion and start the bootp daemon.
The application was unable to initialize the bootp
information. The AccuSwitch application could not
determine its IP address.
Make sure a bootp server is running and a valid con-
figuration is activated.
6E Unable to initialize the control cen-
ter. Activate a valid configuration
and start the bootp daemon.
The application was unable to initialize the bootp
information.
The AccuSwitch application could not find a valid con-
figuration file.
Make sure a bootp server is running and a valid con-
figuration is activated.
6F Unable to initialize Configuration
Upload.
The application was unable to initialize the Configura-
tion Upload.
70 Can't find host name for %s in host
table.
A host name was specified without an IP address.
The host name was not found in the hostname table.
This time server will be inactive.
Table 22. Messages 61 to 68
Message Number Short Message Detailed Description