Instruction manual

278 JUPITER CM-4400 Control Module Installation and Operating Manual
Appendix A — CM-4400 Specifications
Rear panel connections
1, Video Out (VGA) (15-pin HD female)
1, SMPTE Time Code In (XLR female)
1, Sync (reference), 1 V P-P to 4 V P-P, looping (BNC)
1, Alarm (SMPTE 269M-1999)
8, Serial Ports (RS-422/ESbus) (9-pin D female)†
1, Redundant (control) (15-pin D female)
1, Grass Valley router Crosspoint (XPT) bus, looping (15-pin D
female)
1, LAN (10/100baseT) (RJ-45)
Power requirements: 100 to 240 VAC 50-60 Hz auto ranging, 0.4 A
Environmental: Operational range, 0 to
40 degrees Celsius. Humidity (non-
condensing) 95% max.
Matrix Router Control Buses
Matrix router bus controller: CM-4400 System Controller
Protocols supported:
Crosspoint (XPT) bus
Cable/connectors: 10-conductor twisted pair plus ground / 15-pin D
Routers supported:
•Apex
Concerto (with CRS-MC-C2 Controller Module)
•GS 400
•Mars
•SDR 400
•Trinix
•Venus
8 Serial ports, each port is capable of controlling a different third-party
router or Grass Valley router (That is, Acapella or Horizon protocol con-
trolled router).
Power requirements: 117/220 VAC, 0.25/0.125 A