Instruction manual
JUPITER CM-4400 Control Module Installation and Operating Manual 297
Pro-Bel SW-P-08 Protocol
Follow these steps to enter or modify the Serial Protocol table:
1. Select the Serial Protocol option from the Jupiter menu (Jupiter > Serial
Protocol). The Serial Protocol table will then open (Figure 234).
Figure 234. Example of the Serial Protocol Table
2. Double-click the protocol box that is associated with the Serial port. A
drop-down list will show the possible protocol types.
3. Select the P08 (SWP-08 Control Panel) protocol.
4. Click anywhere else in the table to close the entry. The default Baud
rates will be selected automatically; however, the Baud rate may be
changed by clicking the drop down menu (Figure 235).
Figure 235. The P08(SW-P-08 Control Panel) Protocol on The Serial Protocol Table
5. Click the Apply button and then save your changes.
Note The serial line parameters are:
• 38400 Baud
•8 data bits
• No parity
• 1 stop bit
• The baud rate is adjustable
Entering MPK information
You will need to make entries in the MPK Devices table for the port to asso-
ciate the Input, Output and Level sets. The Device Type is Serial with a
Ser
ial Input and an Output set. The level type is cp3000.
Protocol
Baud Rate