Instruction manual

JUPITER CM-4400 Control Module Installation and Operating Manual 301
Pro-Bel SW-P-08 Protocol
The above table will start over after 100.
Entering Serial Protocol information
The steps to configure Jupiter for Remote router control are similar to the
steps to control Jupiter. That is, adding entries in the Serial Protocol table.
Note These steps assume that the CM-4400 has been configured properly. For
steps to configure a CM-4400 seeThe Configurator Application on page 107.
In most cases, you will need to modify the Serial Protocol set that is cur-
rently active; if so, Grass V
alley recommends that you a copy for editing.
Note On the top of the Jupiter Configurator window on the title bar, you will see the
name of the Configuration set. Ensure that the configuration set that is
opened is the one that you want to change.
Follow these steps to enter or modify the Serial Protocol table:
1. Select the Serial Protocol option from the Jupiter menu (Jupiter> Serial
Protocol). The Serial Protocol table will then open (Figure 234).
17 1 1 53 3 5 89 5 9
18 1 2
54 3 6 90 5 10
19 1 3
55 3 7 91 5 11
20 1 4
56 3 8 92 5 12
21 1 5
57 3 9 93 5 13
22 1 6
58 3 10 94 5 14
23 1 7
59 3 11 95 5 15
24 1 8
60 3 12 96 6 0
25 1 9
61 3 13 97 6 1
26 1 10
62 3 14 98 6 2
27 1 11
63 3 15 99 6 3
28 1 12
64 4 0
29 1 13 65 4 1
30 1 14 66 4 2
31 1 15 67 4 3
32 2 0 68 4 4
33 2 1 69 4 5
34 2 2 70 4 6
35 2 3 71 4 7
Table 33. Remote Router Values for Physical Level (0 - 99), Matrix, and Level
PLvl Matrix Level
PLvl Matrix Level PLvl Matrix Level