Instruction manual

304 JUPITER CM-4400 Control Module Installation and Operating Manual
Appendix B — Connecting Legacy and 3rd Party Routers
P08 (SW-P-08 Control Panel)
The P08 (SW-P-08 Control Panel) driver will receive the following informa-
tion:
The P08 (SW-P-08 Control Panel) sends the following information:
When the P08 (SW-P-08 Control Panel) dr
iver is used, the following will
occur:
The control panel level value is a combin
ation of the Pro-Bel SW-P-08
matrix and level values. The level is the matrix times 16 plus the level.
The interface ACKS all messages that are received correctly even if they
are not implemented.
The system responds to a CONNECT message with a CONNECTED
message only when the cross point is valid. Unsolicited CONNECTED
messages will be sent for confirmed TAKES to outputs in the control
panel set.
Table 36. P08 (SW-P-08 Control Panel) Received Information
Message Value
CONNECT 2
CONNECT_EXT 130
INTERROGATE 1
INTERROGATE_EXT 129
CONNECTED 4
CONNECTED_EXT 132
Single source name request 101
Single destination name
request
103
Single source name extended 229
Single destination name
extended
231
Table 37. P08 (SW-P-08 Control Panel) Sent Information
Message Value
TALLY 3
TALLY_EXT 131
CONNECTED 4
CONNECTED_EXT 132
Source name response 106
Destination name response 107
Source name response
extended
234
Destination name response
extended
235