JUPITER CM-4400 Control Module Installation and Operating Manual 49
CM-4400 Control System’s Protection Features
Verifying the Replacement CM-4400 is Ready to be Used
Follow these steps to verify that the replacement unit is ready for use:
1. Start the Jupiter Network Suite, if it is not already running.
a. Click the JNS Server button on the top of the JNS Control Console.
The JNS Server screen will then appear. The words “Not
Connected” will be displayed in the red connection indicator next
to the
Connect button.
b. Click the Connect button.
2. Select the Control Center button (JNS Applications > Control Center). The
Control Center window will then appear.
3. Click the Bootp Tab and check that the correct MAC address is being
used for the replacement CM-4400.
a. Go to the TFTP Status tab and look for an indication that the transfer
was successful (“100% complete”). Proceed with the steps if these
indications are correct.
4. Swap control to the replacement CM-4400 by pressing the Activate
button on the front of the CM-4400 (Figure 3 on page 33).
5. Confirm system operation. Assuming all is well leave the replacement
CM-4400 in control of the system.
The installation of the replacem
ent CM-4400 is now complete.
Correcting Problems with the Replacement CM-4400
Follow these steps if you encounter any problems:
1. Return the control immediately to the non-replacement CM-4400.
2. Unplug the replacement CM-4400
3. Check all cabling, and reapply power. It may be necessary to download
a new configuration set if these steps fail to eliminate the fault. See
Validating, Compiling, and Activating (Downloading) a Configuration Set on
page 133 for more information.
If problems persist, contact Grass Valley Technical Support (see Contacting
Grass Valley on
page 4).