58 JUPITER CM-4400 Control Module Installation and Operating Manual
Section 2 — Hardware Installation
Redundant Installation
Some Encore systems may be equipped with redundant System Controller
Boards (SCBs). In this case, the recommended arrangement is to install a
redundant CM-4400 and connect the CMs to the SCBs with a BOP 4000
Break Out Panel. See Figure22. Details of the Encore connection are pre-
sented below.
Figure 22. Connection to Redundant Encore Control System
The Double-Y Cable
A Grass Valley Cat5 cable kit is available in two versions:
If the System Controller Board (SCB) is
the old style (071 0884 xx
series), order kit 174 8216 xx.
If the SCB is the new style (071 1000 xx series), order kit 174 8217 xx.
The factory cable must be used with a custom
er-supplied adapter, wired as
shown in Figure 20 on page 57. Note that the cables in this kit are eight
inches long. Further instructions ar
e provided with the cable kit.
The rack mount BOP 4000 Break Out Panel / cable kit
is available for
making Y connections to redundant CMs. For more information, see Alarms
in a Redundant CM-4400 Installation on
page 46 and Figure23.
to routing switcher
Encore Redundant SCBs
Redundant CM-4400 System Controllers
RS−422
ports
Serial Port
Serial Port
BOP 4000 Break Out Panel
NALNAL
yp