Instruction manual

JUPITER CM-4400 Control Module Installation and Operating Manual 75
Installing a File Server PC
The CC 2010 Matrix (Crosspoint Bus) Cable
Grass Valley’s Trinix, Concerto, and Venus Routing switchers use a very
fast, reliable, and proprietary connection called the Crosspoint Bus (XPT).
The CC 2010 Matrix (Crosspoint Bus) cable
is used to connect the CM-4400
to the routing switcher’s Crosspoint Bus. Depending on the size of the
switcher, this bus may require intermediate buffering through the CB 3000
Control Buffer.
The CC 2010 is a 10-conductor (plus ground) cable with an instal
led 15-pin
D male connectors. Table 3 identifies several ready-made cables that are
available from Grass Valley:
All Crosspoint Bus connectors on the r
ear-panel are female type with 15-
pin D connections.
Note If you are connecting to a Concerto or Trinix router, the crosspoint bus must
be terminated using a Crosspoint Bus Terminator. This connector must be at
the point that is farthest from the control processor. No termination is
required for other routers.
For specific wiring instructions concerning CC 2010 Crosspoint Bus Cables,
please refer to your routing switcher’s installation manual.
Crosspoint Bus Cables Diagram
For those who wish to prepare their own cables, pin-outs are shown in
Figure34. The cable itself should be Belden
9505 or equivalent. Steps
should be taken to shield the connectors
. For example, using EMI housings
or ferrite cores. Ferrite core details are given in VDE EMI/RFI Modifications
to Matrix Cables on pa
ge 76.
Table 3. Cable lengths
Length Part #
1 foot (0.3 m) 01-048592-001
2 feet (0.6 m) 01-048592-002
3 feet (0.9 m) 01-048592-003
10 feet (3 m) 01-048592-010
25 feet (7.6 m) 01-048592-025
50 feet (15.2 m) 01-048592-050
100 feet (30 m) 01-048592-100