User manual
MIDI KEYBOARD CMK-2 APPENDIX-B AHLBORN MESSAGES
CMK-2 Manual 1.5.doc 2009 CLASSIC ORGAN WORKS 51
Table 17: Additional Piston input commands
[8]
Group No.
Data sent:
Off ----> On
Data sent:
On ----> Off
Description Note
5A Cn 40 Ahlborn – Division Cancel 1
5E BF 47 46 BF 47 06 SET piston 2
5F BF 47 42 BF 47 02 SFZ control 3
NOTES:
1) Prog. Change 51-85 (32h - 54h) on a Division Channel (1-4) will actually act as a Divisional Cancel.
2) Works with General Pistons to allow setting them via remote (MIDI) control, i.e., press & hold SET; press and release a
General, then release SET; to store a new registration.
3) Should allow for a lamp output for this. Also, possible another input function which would act as a "reversible"; i.e., push-
ON, push-OFF.:
4) n = Channel number used by Ahlborn stop On/Off messages; defaults to 16 (Fh).
Table 18: Analog input function commands
[8]
Input Data sent Function Div. Description Note
1 CF ss Crescendo Crescendo 1
2 B0 07 aa Sw Ahlborn – Division Volume 2
3 B1 07 aa Gt Ahlborn – Division Volume 2
4 B2 07 aa Ch Ahlborn – Division Volume 2
5 B3 07 aa Pd Ahlborn – Division Volume 2
6
Bn 65 00 64
01 06 xx 26 yy
Tuning
Tuning and/or Temperature
Sensor
3
NOTES:
1) "ss" is the Crescendo stage, where Off=64h, Stage#1=65h, #2=66h, etc., #11=6Fh, #12=77h, #13=78h, etc., #20=7Fh.
2) Ahlborn modules use Controller #7 for expression. Outputs on Ahlborn channels (1-4) must be configurable, connecting to
analog inputs 2-5. aa = volume value from an analog input, where 0<aa<127.