ENGLISH GLOW UP & FLIGHT CASE C TW W C71050 C71055 C71060 F21230 INSTRUCTIONS MANUAL Page 2 3 12 12 13 14 16 17 18 27 28 28 29 31 32 32 33 CONTENTS Contents Safety information GLOW UP EN IT FR DE Safety information FLIGHT CASE EN IT FR DE Unpacking and preparation Removal of the protective film Installation and start-up Control panel Button function Preset colors for Stand Alone “GLOWUP C” Menu setting Operating modes RDM Controls implemented for GLOWUP series Manual zoom - Antenna Maintenance Optio
EN SAFETY INFORMATION GLOW UP • Installation Make sure all parts for fixing the projector are in a good state of repair. Make sure the point of anchorage is stable before positioning the projector. The safety chain must be properly hooked onto the fitting and secured to the framework, so that, if the primary support system fails, the fitting falls as little as possible. If the safety chain gets used, it needs to be replaced with a genuine spare.
• Battery This product contains a lithium iron tetraphosphate rechargeable battery. To protect the environment, please discard the battery at the end of its life cycle according to current law. LiFePO4 Disposing This product is supplied in compliance with European Directive 2012/19/EU - Waste Electrical and Electronic Equipment (WEEE). To preserve the environment please dispose/recycle this product at the end of its life according to the local regulation.
IT INFORMAZIONI DI SICUREZZA GLOW UP • Installazione Assicurarsi che tutte le parti per il fissaggio del proiettore siano in buona condizione. Assicurarsi della stabilità del punto di ancoraggio prima di posizionare il proiettore. La fune di sicurezza, debitamente agganciata all’apparecchio e fissata alla struttura di sostegno, deve essere installata in modo che, in caso di cedimento del sistema di supporto primario, si abbia la minor caduta possibile dell’apparecchio.
• Batteria Questo prodotto contiene una batteria ricaricabile Litio Ferro Tetrafosfato. A tutela dell'ambiente si prega di smaltire la batteria a fine vita in conformità alla normativa vigente. LiFePO4 Smaltimento Questo dispositivo è conforme alla Direttiva Europea 2012/19/UE - Rifiuti di apparecchiature elettriche ed elettroniche (RAEE). Nel rispetto dell'ambiente, smaltire/riciclare il prodotto al termine del suo ciclo di vita secondo le disposizioni di legge locali.
FR CONSIGNES DE SÉCURITÉ GLOW UP • Installation S’assurer que toutes les pièces pour la fixation du projecteur sont en bon état. S’assurer de la stabilité du point d’ancrage avant de positionner le projecteur. Le câble de sécurité, à fixer correctement à l’appareil et à la structure de support, doit être installé de façon à ce que, en cas de rupture du système de support principal, la chute de l’appareil soit la plus limitée possible.
LiFePO4 • Batterie Ce produit contient une batterie rechargeable au tétraphosphate de fer au lithium. Une fois la batterie parvenue à la fin de sa durée de vie, procéder à son élimination conformément à la norme en vigueur de manière à éviter toute pollution. Élimination Ce dispositif est conforme à la Directive Européenne 2012/19/UE – Déchets d’équipements électriques et électroniques (DEEE).
DE INFORMATIONEN ZUR SICHERHEIT GLOW UP • Installation Sicherstellen, dass alle Teile für die Befestigung des Projektors in einwandfreiem Zustand sind. Vor der Installation des Projektors die Stabilität der Verankerungsstelle überprüfen. Das korrekt am Gerät eingehakte und an der Haltestruktur befestigte Sicherheitsseil muss so installiert werden, dass bei einem Nachgeben der Haupthalterung die Fallhöhe des Gerätes so gering wie möglich ist.
• Batterie Dieses Produkt enthält eine wiederaufladbare Lithium-Eisenphosphat-Batterie. Zum Schutz der Umwelt bitten wir Sie, diese Batterie, nachdem sie verbraucht ist, gemäß den geltenden Vorschriften zu entsorgen. LiFePO4 Entsorgung Diese Vorrichtung entspricht der Europäischen Richtlinie 2012/19/UE - Abfall von elektrischen und elektronischen Gerätschaften (RAEE). Das Produkt am Ende seines Lebenszyklus unter Berücksichtigung der Umwelt nach den lokalen Gesetzesvorschriften entsorgen/recyceln.
ES INFORMACIONES DE SEGURIDAD GLOW UP • Instalación Asegúrese de que todos los elementos de fijación del proyector estén en buenas condiciones. Controle la estabilidad del punto de anclaje antes de instalar el proyector. La cuerda de seguridad, correctamente enganchada al aparato y fijada a la estructura de soporte, debe colocarse de modo que, si el soporte principal cede, el aparato sufra la menor caída posible. En caso de desgaste de la cuerda de seguridad, sustitúyala por el recambio original.
• Batería Este producto contiene una batería recargable plomo-ácido o de Litio Tetrafosfato Hierro. Para proteger el ambiente se ruega eliminar la batería conforme a la normativa vigente. LiFePO4 Eliminación Este dispositivo es conforme a la Directiva Europea 2012/19/UE - Residuos de equipos eléctricos y electrónicos (RAEE). Con el fin de respetar el ambiente, eliminar/reciclar el producto al final de su ciclo de vida según las disposiciones de ley locales.
UNPACKING AND PREPARATION 1 C71050 C TW C71055 C71060 W GLOW UP ® ITALIANO & FLIGHT MANUALE EL PR F21230 CASE IST002/001 ZIONI DI ISTRU Y AR IMIN INDICE o Contenut oni di sicurezza Informazi izione e predispos Disimballo in funzione ne e messa Installazio Pag.
INSTALLATION AND START-UP 3 Projector installation - Fig. 3 The projector can be installed on the floor resting on specific rubber feet, on a truss, on the ceiling or wall. WARNING: the safety chain must be installed except when the projector rests on the floor. (Code 105015/801 available upon request). This must be secured to the projector support structure and then hooked to the fastening point at the centre of the base. 4 4 1 1 3 3 2 2 Connecting and disconnecting the power cord - Fig.
CONTROL PANEL 5 Power Supply L N Connections to the power mains - Fig. 5 6 DMX 512 5 PIN DMX 512 5 4 3 1 2 SCREEN SIGNAL SIGNAL Connections to the control signal line (DMX) - Fig. 6 Use a cable conforming to specifications EIA RS-485: 2-pole twisted, shielded, 120Ω characteristic impedance, 22-24 AWG, low capacity. Do not use microphone cable or other cable with characteristics differing from those specified. End connections must be made using XLR type 3-pin male/female connectors.
When GlowUp is in idle status the information page will appear on the display: DMX Address ADDR 001 STND Operating mode (see page 23) Yy Link status (Wireless or Wired) BAT 40% Time or percent remaining of the battery charge FRES/W Factory reset? Y/N Warning Radio W42 (radio board not found) Display symbology - (Link Status) W43 (radio board not interact) If errors W42/W43 appear on the display, do an RDM Discovery (see page 16) to see if the error disappears.
BUTTON FUNCTION By pressing any button when Glow Up is in idle status, the BUTTON FUNCTION menu is accessed. Symbol SET or II MOD Function Setting Play/Pause Stop Mode ?? SET BAT 40% MOD Press SET SELECT to access the menus: Program DMX Address Advanced (Menu use is recommended for qualified technical personnel.
PRESET COLORS FOR STAND ALONE “GLOWUP C” Colour Reference 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 LEE 101 LEE 103 LEE 105 LEE 107 LEE 111 LEE 113 LEE 115 LEE 116 LEE 119 LEE 128 LEE 132 LEE 134 LEE 135 LEE 136 LEE 147 LEE 180 LEE 156 LEE 079 LEE 194 LEE 024 LEE 017 LEE 019 LEE 108 LEE 126 LEE 141 ROSCO 378 ROSCO 358 ROSCO 081 ROSCO 066 ROSCO 030 ROSCO 318 ROSCO 332 ROSCO 034 ROSCO 039 RGBW
MENU SETTING Main Menu Level 1 Level 2 Level 3 Edit Scene Scene 1-10 Program Edit Sequence Choices / Values Preset Colors 0 - 255 Red 0 - 255 Green Blue White 0 - 255 0 - 255 0 - 255 Dimmer 0 - 255 Stop-Strobe 0 - 255 Æ Add step Æ Delete step Æ Modify step Æ Æ Memory x ? Æ Æ Memory erase ? Æ Æ 1-506 Æ Unlink Transmitter Memory 1-10 DMX Recorder DMX Address Level 4 Æ Radio Æ Link Receivers Æ Unlink Receiver Æ TX Mode Æ RDM Discovery Slave Priority Cable Wire
Main Menu Level 1 Level 3 Level 4 Choices / Values Æ Æ Color Æ Æ Tunable White Æ Æ White Æ Æ Color LR Æ Æ Tunable White LR Æ Æ White LR Æ Æ Appl. Upload Æ Æ Boot upload Æ Æ Transfer Set Charge Battery hour Discharge Battery hour Æ hh:mm Æ hh:mm Æ Voltage Æ Current Level 2 Set Model FW Uploader SET Advanced Access Code 1234 Battery Monitor Information Æ Temperature Æ Max temperature Æ hh:mm Æ Appl.
Select Enter DOWN UP SHORT-CUT KEYS MENU Short-Cut Key ------------------------------------------- Press ENTER and DOWN to switch off Glow UP (Switch off ? Yes/No). - Press ENTER and UP to quickly open DMX address settings. - Press ENTER and hold down for several seconds with GlowUP in idle conditions to restore ‘’Factory’’ settings. (Factory Reset). ‘’Factory Reset’’ is only applied to ‘’Current’’ Preset and not to ‘’User’’ Preset.
SET MENU Press Select twice with GlowUP in idle conditions to open the SET menu SET – PROGRAM ………. EDIT SCENE To create/overwrite/modify a SCENE customised by the user: 1 to 10 scenes can be customised using each single GlowUP channel. • • • • • • Press ENTER to display Scene 1. Use the UP and DOWN keys to select from the ten available SCENES. Press ENTER to open the SCENE. A bit value can be associated with each GlowUp channel inside each SCENE using the UP and DOWN keys.
SET ………. ADVANCED To enable the "Menu Advanced" enter the code (1234) using the UP, DOWN and ENTER keys. SET - ADVANCED – SETUP ……….
SET - ADVANCED – SETUP ………. LOCK OPTION It lets you assign a lock password, requested at each projector start up (Lock). The same password can be used to access the ''Menu Advanced''. Press ENTER and open the ‘’Lock’’ menu to enable ON or disable OFF the password request at start up. • Select ON to enable. The previously entered password is displayed. Use the UP and DOWN and ENTER keys to enter the desired numeric password. • By selecting OFF, no password will be requested at projector start up.
SET - ADVANCED – SETUP ………. BATTERY DISPLAY Allows you to select how to display the battery charge in idle status. • Press ENTER - current settings are displayed. • Use the UP and DOWN keys to select from the 3 available options: Automatic: displays the remaining battery charge in hours or as a percentage. Percentual: displays the percentage of remaining battery charge. Time left: displays the remaining time of the battery charge in hours.
SET - ADVANCED – INFORMATION ………. DISCHARGE BATTERY HOURS Displays total projector battery powered operating hours from construction to date. SET - ADVANCED – INFORMATION ………. BATTERY MONITOR Allows you to display the battery voltage and current status. SET - ADVANCED – INFORMATION ……….
SET - ADVANCED – RESET ………. RESET TO DMX WIRELESS Resets GlowUP and automatically sets DMX WIRELESS settings. Default settings after Reset are the following: · “Master Output”-> "Cable + Wireless" "Repeater"-> "Disable" · "Repeater"-> "Function"->"Repeat & Play" · · "Repeater"-> "Direction"->"Wirel. to Cable" · “DMX address” = 1 · "Display"-> Off · “Contrast” = 5 · “MOD”-> "Stand Alone/DMX" SET - ADVANCED – RESET ……….
OPERATING MODES Operating Mode Stand Alone DMX Descrizione Does not receive DMX and executes only the Play Receives DMX Slave Glow UP receives (on address 1) if the GlowUp Master is set in Play sequences. Slave Master Repeater GLOW UP Display STND DMX SLV Slave Glow UP receives on its DMX address if GlowUp Master transmits a recording DMX Broadcasts sequences or recording DMX Receives and repeat, depending on the configuration set in the '' Advance Menu’’.
RDM CONTROLS IMPLEMENTED FOR GLOWUP SERIES Control PID GET SET Description controller side DEVICE_INFO 0x0060 X IDENTIFY_DEVICE 0x1000 DMX_START_ADDRESS 0x00F0 X SOFTWARE_VERSION_LABEL 0x00C0 X Reads the firmware version SUPPORTED_PARAMETERS 0x0050 X Gathers the PIDS on the non-basic controls PARAMETER_DESCRIPTION 0x0051 X Gathers information on the controls related to the manufacturer DMX_PERSONALITY 0x00E0 X DMX_PERSONALITY_DESCRIPTION 0x00E1 X Reads the description of the c
MAINTENANCE 9 4 3 1 2 Charging glow up - Fig. 9 From 1 to 6 Glow Ups can be simultaneously charged by appropriately connecting and powering the flight-case. 10 1 Fuse 6,3x32mm 3AT 250Vac (030471) 2 Fuse 6,3x32mm 10AT 250Vac (030470) Replacing flight case fuses - Fig. 10 Each flight-case has 2 fuses associated with the main power cord connection and one fuse for each Glow UP charge station.
11 3 2 1 5 6 4 Battery removal - Fig. 11 This product contains lithium iron tetraphosphate rechargeable battery. To protect the environment, please discard the battery at the end of its working life according to current law. LiFePO4 GLOW UP Notes on how to achieve correct battery operations 1) Do not tamper with the control electronic circuit, do not tamper with the battery, do not short-circuit the battery.
12 Parts requiring frequent cleaning. Periodic cleaning - Fig. 12 To ensure optimal operation and performance for a long time it is essential to periodically clean the parts subject to dust and grease deposits. The frequency with which the following operations are to be carried out depends on various factors such as wear and the work environment quality (air humidity, dust, salinity, etc.). To remove dirt from external parts, use a soft cloth dampened with any liquid glass cleaning detergent.
Source 4 10 W MC-E Cree leds TECHNICAL DATA Input Power 170 VA Led pilot power 40W Optics Optic zoom, manually adjustable, magnetic support for any additional diffusers LED color temperature 5700K GlowUP C 6000K GlowUP W 6200K cool white GlowUp TW 2700K warm white GlowUp TW 4200K cool+warm white GlowUp TW 226 (8.90") Weight 7.5 Kg (16.
CHANNEL FUNCTIONS GLOW UP C CHANNEL 1 CHANNEL MODE 2 RED 4 BLUE 6 DIMMER 3 GREEN 5 WHITE 7 STOP / STROBE MACRO COLOR GLOW UP TW CHANNEL 1 2 3 INDEPENDENT CHANNEL MODE (Colour temperature) CONSTANT INTENSITY MAX INTENSITY COOL WHITE 6200K TUNABLE WHITE TUNABLE WHITE WARM WHITE 2700K DIMMER DIMMER STOP / STROBE STOP / STROBE STOP / STROBE GLOW UP W CHANNEL 1 2 GLOW UP CHANNEL MODE DIMMER STOP / STROBE 33 Continued ➔
GLOW UP C • MACRO COLOR - channel 7 • COLOUR MIXING - channel 1 - 2 - 3 CHANNEL 1 RED CHANNEL 2 CHANNEL 3 GREEN BLUE BIT EFFECT 255 MAX BRIGHTNESS 0 LED OFF • WHITE - channel 4 BIT EFFECT 255 MAX BRIGHTNESS 0 LED OFF • DIMMER - channel 5 BIT EFFECT 255 MAX BRIGHTNESS 0 LED OFF • STOP / STROBE - channel 6 GLOW UP 34 BIT EFFECT 248 - 255 240 - 247 232 - 239 224 - 231 220 - 223 216 - 219 212 - 215 208 - 211 204 - 207 200 - 203 196 - 199 192 - 195 188 - 191 184 - 187 180 - 183 176
GLOW UP TW INDEPENDENT MODE CONSTANT INTENSITY & MAX INTENSITY MODE INDEPENDENT CONSTANT INTENSITY MAX INTENSITY COOL WHITE 6200K TUNABLE WHITE TUNABLE WHITE WARM WHITE 2700K DIMMER DIMMER STOP / STROBE STOP / STROBE STOP / STROBE CONSTANT INTENSITY 100 COOL • COOL WHITE - channel 1 EFFECT 255 MAX BRIGHTNESS 0 50 50 WARM 100 50 0 6200K 0 2700K BIT 4200K 0 2700K EFFECT 255 WARM WHITE 0 COOL WHITE • DIMMER - channel 2 BIT EFFECT BIT EFFECT 255 MAX BRIGHTNESS 255 MAX B
GLOW UP W • DIMMER - channel 1 BIT EFFECT 255 MAX BRIGHTNESS 0 LED OFF CLAY PAKY S.p.A. - Via Pastrengo, 3/b - 24068 Seriate (BG) Italy - Tel. +39-035-654311 - Fax +39-035-301876 - www.claypaky.it IST002/001 – EN - Rev.