Mounting the Furnace
After selecting a safe and appropriate location for your furnace, construct the mounting system as
required by the location and the following specifications.
Ceiling Mounting
WARNING: To prevent serious personal injury, ensure that your furnace mounting system can
safely bear the suspended weight of the furnace and allow safe servicing of furnace components.
Use adequately sized square tubing or angle iron bridged across sufficient structural members to safely support
the furnace.
1. Refer to Figures 4A and 4B.
2. Follow the instructions as provided in the diagrams.
3. Use a spirit level to make sure the cabinet is level side to side and front to back.
Selecting a Location (continued)
Figure 4C - Clearances from Combustibles
2
2
0
-
2
4
0
5
0
-
6
0
H
z
3
W
N
r
.
0
5
7
H
7
0
3
6
T
y
p
e
B
H
O
6
4
D
a
n
f
o
s
s
t
s
1
0
s
46 cm (18")
OTHER SIDE
(WITHOUT AIR
DISCHARGE)
153 cm (60")
FRONT
31 cm (12")
TOP
5 cm (2")
REAR
46 cm (18")
CHIMNEY
CONNECTOR
153 cm (60")
AIR DISCHARGE
SIDE
244 cm (96") BOTTOM, IF THERE IS POTENTIAL
FOR GASOLINE FUMES
61 cm (24") BOTTOM, IF THERE IS NO
POTENTIAL FOR GAS FUMES
(NOTE: 97 cm (38") FOR BOTTOM
AIR DISCHARGE)
I88946