SECTION 6: STARTING AND ADJUSTING THE BURNER
Understanding Burner Startup and Adjustment
Starting and adjusting the burner involves a series of separate procedures which must be accomplished
in sequence without interruption. Review all the procedures before attempting burner startup and
adjustment, paying careful attention to safety information statements.
Preparing the Burner for Startup
1. Turn the switch on the wall thermostat OFF.
NOTE: If your thermostat does not have an OFF setting, disconnect one thermostat wire so
the burner will not run.
2. Turn the main power to the furnace ON.
3. Wait at least 15 minutes until the preheater block is thoroughly warmed up. (Feel the back of the
burner box to make sure the preheater is sufficiently warm. The proving switch on the preheater
block will not allow the
burner to start until the block
is hot.)
NOTE: The preheater block
will remain warm as long as
power is supplied to the
burner. If the main power
supply is ever turned OFF,
you must wait at least 15
minutes until the preheater
block is thoroughly warm
before starting the burner.
4. Refer to Figure 6A to locate
the air regulator.
Loosen the locking nut on
the air regulator.
5. Turn the adjustment knob
on the air regulator
counterclockwise until 12mm
(1/2") of the threads on the
knob are exposed. DO NOT
back the knob all the way out.
Figure 6A - Component Detail of the CB-500 Burner
AIR REGULATOR
LOCKING NUT
COVER PLATE
AIR GAUGE
OIL GAUGE
I88901
AIR BAND
COMBUSTION