VENTILATORS MODELS: VH30100 30-100 CFM HRV VH30120R 30-120 CFM HRV with Recirculation VH30160 30-160 CFM HRV VH30160R 30-160 CFM HRV with Recirculation VH70220 70-220 CFM HRV VE30100 30-100 CFM ERV VE30160 30-160 CFM ERV VH SERIES HEAT RECOVERY VENTILATORS VE SERIES ENERGY RECOVERY VENTILATORS Homeowner's Guide VE70220 70-220 CFM ERV i IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. THIS GUIDE TO BE LEFT WITH EQUIPMENT OWNER. IO-VENT-HG WWW.CLEANCOMFORT.
TABLE OF CONTENTS SAFETY CONSIDERATIONS.................................3 VENTILATOR OPERATION..................................4 TYPES OF INSTALLATIONS ................................4 VENTILATION SYSTEM.......................................5 VENTILATOR CONTROL.....................................6 REMOTE WALL CONTROLS ...............................8 TROUBLESHOOTING..........................................9 MAINTENANCE.................................................10 WARRANTY........................
SAFETY CONSIDERATIONS i= WARNING! • To reduce the risk of injury, disconnect power to the ventilation system while performing service on the unit. There are impeller wheels turning at a very high speed that must fully stop rotating prior to accessing the inside of the unit. • To reduce the risk of electric shock or fire, do not perform any service to the HRV system other than as stated in the operating manual instructions.
VENTILATOR OPERATION This ventilation system has been engineered and designed to improve the indoor air quality in your home. It does this by replacing stale, polluted indoor air with fresh filtered air from the outdoors and reducing excess humidity inside the home.
VENTILATION SYSTEM Ventilation System Ventilation System with Recirculation Mode SIDE VIEW SIDE VIEW All models except VH30120R and VH30160R Fresh Air From Outside VH30120R and VH30160R only E Recirculation of warm ambient air Exhaust Air From Home A Fresh Air From Outside C A Exhaust Air To Outside Fresh Air To Home D B B Compact Ventilation System VH30100 and VE30100 Models TOP VIEW Exhaust Air To Outside Fresh Air To Home B D A C Air frais provenant Fresh Air de l’extérieur From O
VENTILATION CONTROL The control mounted on the ventilator serves two purposes: 1. Acts as a mode selector (OFF, CONT, and INTER) • INTER (Intermittent): When the selector switch is in the Intermittent (INTER) position, the ventilation system will only run when there is a request for ventilation from a remote wall control.
OPERATING YOUR WALL CONTROLS VHP Ventilation Controls The humidity sensor dial on a VHP remote wall control should be set relative to the outdoor conditions. During the winter season, the humidity sensor dial should be set within the comfort zone range, between 30% and 60% relative humidity. If the home has excess dryness, turn the humidity sensor dial counterclockwise to a higher setting. If the home has excess humidity, turn the humidity sensor dial clockwise to a lower setting.
OPERATING YOUR WALL CONTROLS VHP-RD3D Deluxe Remote Ventilation Wall Control Features • Humidity Sensor Dial to control ventilation operation • Compatible with Clean Comfort VH30120R and VH30160R HRVs models only • Range Control (OFF, NORMAL and REDUCED) • Mode Control (INTERM, RECIRC and CONT) • Green LED light on = OVERRIDE • Orange LED light on = CONT/INTERM Range Selector Switch (OFF/NORMAL/REDUCED) • OFF - Turns off the ventilation system • NORMAL - The ventilation system operates at the Continuous (C
TROUBLESHOOTING Question / Item Diagnosis / Solution • Ventilator not running • Verify breaker in main electrical panel • Verify the HRV or ERV is in the ON position • Verify all wall controls connected to the ventilator are activated to supply power to the unit • Unplug ventilator and verify that the wall control is wired correctly to the connection box on the side of the unit • Verify main outlet polarization • Air is too dry • Increase the humidity level on the wall control (Turn dial towards 60%)
MAINTENANCE ROUTINE MAINTENANCE Seven-Step Maintenance Schedule With routine preventative maintenance, you can avoid unnecessary problems, ensure the effectiveness of your ventilator, and prolong its life. 4. Clean the condensate drain and pan Twice a year, check the condensate drain, pan and tubing to ensure that they are open and free-flowing. The tubing can be disconnected for cleaning.
WARRANTY Limited Warranties Coverage Daikin North America LLC (“Daikin”) warrants this product, to the original consumer, to be free from defects in materials and workmanship under normal use and service, for the applicable time periods listed below.
VENTILATORS Our continuing commitment to quality products may mean a change in specifications without notice. © 2015 • • Houston, Texas • Printed in the USA. 12 WWW.CLEANCOMFORT.