VE Series Owners Manual
Fresh Air
From Outside
Exhaust Air
To Outside
Exhaust Air
From Home
Fresh Air
To Home
Air frais provenant
de l’extérieur
Air vicié évacué
à l’extérieur
Évacuation de l’air
vicié vers l’extérieur
Air frais distribué
vers l’intérieur
A
B
C
D
SIDE VIEW
Fresh Air
From Outside
Exhaust Air
To Outside
Exhaust Air
From Home
Fresh Air
To Home
Air frais provenant
de l’extérieur
Air vicié évacué
à l’extérieur
Évacuation de l’air
vicié vers l’extérieur
Air frais distribué
vers l’intérieur
A
B
C
D
Fresh Air
From Outside
Exhaust Air
To Outside
Exhaust Air
From Home
Fresh Air
To Home
Recirculation of warm
ambient air
Recirculation
d’air ambiant
Air frais provenant
de l’extérieur
Air vicié évacué
à l’extérieur
Évacuation de l’air
vicié vers l’extérieur
Air frais distribué
vers l’intérieur
A
B
C
D
SIDE VIEW
WWW.CLEANCOMFORT.COM
5
IO-VENT-HG IO-VENT-HG
VENTILATION SYSTEM
TOP VIEW
Ventilation System
All models except VH30120R and VH30160R
Ventilation System with Recirculation Mode
VH30120R and VH30160R only
Compact Ventilation System
VH30100 and VE30100 Models
• Fresh Air from Outside Port A: Inlet for fresh
outdoor air.
• Exhaust Air to Outside Port B: Outlet for exhausng
stale, humid and polluted air to the outdoors aer
transferring its heat through the recovery core.
• Exhaust Air From Home Port C: Exhausts stale, humid
and polluted air to the outside from mulple
locaons of the home or from the return air of the
forced air system, prior to passing through the heat
recovery core. e.g. Bathroom, laundry room etc.
• Fresh Air to Home Port D: Introduces and distributes
clean and fresh air to your home. The home's fresh air
registers are normally installed in the main living areas
or in the return/supply duct of the forced air system.
e.g. living room, bedrooms, recreaon room etc.
• 5th Port on "R" Models only E: Recirculaon port; used
during defrost sequence or when the homeowner has se-
lected RECIRC mode on the remote wall control, if installed.
• Venlaon Control: Use for selecng venlaon modes
as well as adjusng connuous (CONT) air ow rates:
Increasing
(+)/Decreasing (-)
• German-Engineered Motors (2): Designed with high
performance and reliability, they are maintenance-free
for your comfort and peace of mind.
• Synthec Filters: Capture large debris from the air
stream and protect your heat recovery core from
potenal obstrucon by these parcles.
• Heat Recovery Core: A cross-ow type that is designed
to transfer the heat between both exhaust and supply
air streams without allowing them to mix. This heat
recovery helps to conserve energy while maintaining a
supply of fresh air to the home, compared to venlang
without heat recovery.
• Energy Recovery Core: An energy recovery core transfers
heat like the heat recovery core plus it transfers latent
energy (humidity) as well. This is parcularly useful for
keeping humidity in the home (during dry winter months)
or out of the home (during humid summer months).
• Condensate Drain Pan and Drainage Hose: Captures the
water that accumulates during the heat transfer and
defrost sequence in the fall, winter and early spring
seasons. A drain hose is connected to the drain pan and
serves to remove the accumulaon of water. It is normal
during summer months to nd no condensaon in
either the drain pan or the drain hose.
• Automac Defrost Sequence: The defrost sequence is
electronically controlled according to the outdoor air
temperature. The sequence is acvated at -5°C (23°F) and
colder. This process helps to prevent ice buildup on the
heat recovery core during winter.
Defrost Sequence of Operations:
VH30120R
• An automac motorized damper closes the fresh air
(supply) and exhaust air ports and opens the recirculaon
damper. This allows the venlator to recirculate the ambi-
ent air in the house while the fresh air motor is turned o.
VH30160R
• An automac motorized damper closes the fresh air
(supply) port, the exhaust fan shuts o, the supply fan
increases its speed according to the outside tempera-
ture, and the venlator draws air from the 5th port
located on the top of the unit.
All other Clean Comfort Ventilators
• Supply fan shuts o and the exhaust fan increases its
speed according to the outside temperature.
E