VE Series Owners Manual

OPERATING YOUR WALL CONTROLS
WWW.CLEANCOMFORT.COM
8
IO-VENT-HG IO-VENT-HG
VHP-RD3D
Deluxe Remote Ventilation Wall Control
Features
Humidity Sensor Dial to control venlaon operaon
Compable with Clean Comfort VH30120R and
VH30160R HRVs models only
Range Control (OFF, NORMAL and REDUCED)
Mode Control (INTERM, RECIRC and CONT)
Green LED light on = OVERRIDE
Orange LED light on = CONT/INTERM
Range Selector Switch (OFF/NORMAL/REDUCED)
OFF - Turns o the venlaon system
NORMAL - The venlaon system operates at the
Connuous (CONT) speed set by the installer
REDUCED - The venlaon system operates at 30%
lower speed when in CONT mode and 15% lower speed
when in OVERRIDE mode
Note: REDUCED mode will not operate below the
minimum low speed of the venlaon system
Mode Selector Switch (INTERM/RECIRC/CONT):
INTERM - When the selector switch is in the INTERM
posion, the venlaon system will sit idle unl there is
a request for venlaon from a remote wall control. At
this me, the unit will run on high speed unl the relave
humidity is below the set point on the wall control or the
VHP-T3 mer, if installed, has completed its me period.
RECIRC – Operates the venlator on Recirculaon mode.
The fresh air intake port of the HRV is closed in order
to recirculate the air within the house, prevenng fresh
outdoor air from entering the house through the HRV.
CONT - Provides connuous venlaon at the
speed set by the installer. The venlaon system will
increase to high speed when the relave humidity is
above the set point on the wall control or the VHP-T3
mer, if installed, has been acvated. This mode is
recommended for best indoor air quality.
VHP-T3
Push Button Timer
Features
20/40/60 minutes of venlaon at high speed
Green LED light on = Venlator is operang in
OVERRIDE (high speed) mode
Operation
Press the buon unl the LED blinks once and then
release. This operates the venlaon system on high
speed for 20 minutes.
Press the buon unl the LED blinks twice and then
release. This operates the venlaon system on high
speed for 40 minutes.
Press the buon unl the LED blinks three mes and
then release. This operates the venlaon system on
high speed for 60 minutes.
To turn o, press the buon once. This will cancel
the programmed venlaon me period and your
venlaon system will return to previous sengs.
Tip: The VHP-T3 model push buon mer allows the
homeowner to temporarily increase venlaon in the
home to reduce airborne pollutants to or lower the
humidity level.
i CAUTION!
It is normal to experience condensaon on your windows
when there are large swings in indoor or outdoor
temperatures, when excess humidity is generated in
the home (e.g. cooking, showers), or when curtains and
blinds are fully closed.