Technical data
instructions for use
make sure the air is dry, otherwise the blasting agent will
form lumps
Set the desired working pressure on the regulator. The compressed air set
willbedisplayedontheManometer.
max. 7 bar, recommended is 2 − 4 bar
air consumption about 150 l / min at 5 bar
Fillblastingagentintothecontainer
make sure the blasting agent is dry
Thelid(15)istobeunscrewedwhenblastingagentislledintothe
container.Usingafunnel,llthecontainerwithblastingagentuptoapprox.
onenger’swidthundertherisingpipeinthemiddleofthecontainer.
Close the container.
Youcanbeginworkbyusingthebuttonontheblastinggun
Blastingstopsbyreleasingthebutton
Onceworkhasbeennished,theunitmustbedisconnectedfromthe
compressed air supply.
during blasting, goggles (face mask), dust mask, breathing
mask and gloves are to be worn
5.6.5 Blasting agent
Asarule,thefollowingtwoagentscanbedeliveredexstock:
• EKS 10:
stronglyabrasive,fastremovingagent–leavesaroughsurface
• MGK 10:
hasamorepolishedeffect–leavesashinysurface
5.7 CONNECTING UP THE AUTOMATIC ELECTROLYTE FEED ON
CLEAN MARKER P AND CLEAN MARKER TP
• plugtheblackplugbelongingtothepumptubingsetintotheconnecting
socket (17)
• pushtheacidtubingsofarintothestainlesssteelconnectionofthebulk-
headstuffingbox(20),thatitcannotfalloutbyitself-pressthesafetyring
(21)atthesametime,holditfirmlyandpushthetubeintotheopening
• pushthe3-polepluginthedrivingpowerconnection(16)andscrewitup
tightly
• unwindasmuchasyouneedoftheacidtubefromtheroller(18)andtipit
into the electrolyte container (19)
Liquidwillonlybefedwhenthebuttononthecleaningheadispressed.
Whenpumping,opentheacidcontaineralittlesothatnegativepressure
cannotbuildupwhentheliquidissuckedupanddamagethepump.On
all Clean Markers equipped with pump the electrolyte is sucked up directly
fromanexternal5/10litrecannister,abottleorawide-neckedcontainer.
Theacidtubingmustthereforebehungintotheelectrolytecontainer.
Operation Manual Clean Marker Brush −Page16