TROUBLESHOOTING
Symptom: Scrubber does not run! No power to the machine!
Problem: Blown fuse/circuit breaker in the building / room has tripped.
Solution: Replace fuse with the same rating. Reset circuit breaker. Make sure no other appliances
are connected on the same circuit as the machine. The machine requires a dedicated 15
amp circuit.
Problem: Frayed cord, damaged plug or loose internal wiring.
Solution: Have an authorized service technician check cord and replace if necessary. Have an
authorized service technician open switch panel and check for loose wire connection.
Symptom: Insufficient vacuuming power!
Problem: Debris caught under squeegee blades.
Solution: Remove debris and wipe blades with clean cloth.
Problem: Vacuum hose not connected.
Solution: Connect hose.
Problem: Tank cover not properly seated or gasket on dome cover is damaged.
Solution: Reseat tank cover correctly or replace gasket.
Problem: Filter in tank cover blocked.
Solution: Clean filter with water.
Problem: Drain plug or recovery tank not properly placed.
Solution: Check drain plug and replace properly.
Problem: Defective vacuum motor (noisy bearing, carbon brush sparking burn out armature and
worn out carbon brush)
Solution: Have an authorized service technician replace vacuum motor and motor gasket.
Symptom: Little or no water flow going to brushes.
Problem: Solution line blocked.
Solution: Flush out solution tank and lines with clean water.
Problem: Solution tank filter clogged.
Solution: Unclog filter.
Problem: Solution tank empty.
Solution: Refill solution tank.