CLEAR-COM ECLIPSE FOR-22 DUAL 4-WIRE INTERFACE INSTRUCTION MANUAL
FOR-22 Dual 4-Wire Interface Instruction Manual © 1997, 2005, 2008 Vitec Group Communications Ltd. All Rights Reserved. Part Number 810306Z Rev. 3 Vitec Group Communications LLC 850 Marina Village Parkway Alameda, CA 94501 U.S.A Vitec Group Communications Ltd 7400 Beach Drive IQ Cambridge Cambridgeshire United Kingdom CB25 9TP Vitec Group Communications Room 1806, Hua Bin Building No. 8 Yong An Dong Li Jian Guo Men Wai Ave Chao Yang District Beijing, P.R.
CONTENTS OPERATING THE FOR-22 INTERFACE . . . . . . . . 1-1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 "Send" Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 "Send Level" LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 "Recv" Controls . . . . . . . . . . . . . . . . . .
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . W-I Warranty Period . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . W-i Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . W-i Warranty Repairs and Returns . . . . . . . . . . . . . . . . . . . . . . . . . . . . W-ii Non-Warranty Repairs and Returns . . . . . . . . . . . . . . . . . . . . . . . .
IMPORTANT SAFETY INSTRUCTIONS For your safety, it is important to read and follow these instructions before operating a FOR-22 dual 4-wire interface: (1) WARNING: To reduce the risk of fire or electric shock, do not expose a FOR-22 dual 4-wire inteface to rain or moisture. Do not operate a FOR-22 dual 4-wire interface near water, or place objects containing liquid on it. Do not expose a FOR-22 dual 4-wire interface to splashing or dripping water.
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN This symbol alerts you to the presence of uninsulated dangerous voltage within the product's enclosure that might be of sufficient magnitude to constitute a risk of electric shock. Do not open the product's case. This symbol informs you that important operating and maintenance instructions are included in the literature accompanying this product.
1 OPERATING THE FOR-22 INTERFACE This chapter describes how to use the FOR-22 dual 4-wire interface. System operators can use this manual once the Eclipse System is correctly installed and configured with the Eclipse Configuration System (ECS) software, and after the FOR-22's internal jumpers are set. For information on configuring the FOR-22 interface, see the separate manual for the Eclipse Configuration System.
The installation chapter of this manual gives more information on interface frames and on wiring the FOR-22 unit to the matrix and to external devices. OPERATION In normal use, the FOR-22 interface does not require operator interaction. Each channel features the same set of front panel controls: • A "send" level control • A "receive" level control • A "send level" LED • A "relay active" LED "SEND" CONTROLS The "send" controls affect the level of the signals from the matrix to the external devices.
2 INSTALLING THE FOR-22 INTERFACE This chapter includes the following topics about installing the FOR-22 interface: • Overview of interface frames and power supplies. • Installing the interface in an interface frame. • Wiring the interface to the matrix and to external devices. • Adjusting the interface’s front-panel controls after installation.
For more information on the IMF-3 frame, refer to its manual in the Eclipse manual set. POWER SUPPLY #1 CH. A Matrix CH. A Matrix CH. A Matrix CH. A Matrix CH. A Matrix CH. A Matrix CH. A Matrix CH. A Matrix CH. A Matrix CH. A Matrix CH. A Matrix CH. A I/O PHONE LINE A CH. A I/O PHONE LINE A CH. A I/O PHONE LINE A CH. A I/O PHONE LINE A CH. A I/O PHONE LINE A CH. A I/O PHONE LINE A CH. A I/O PHONE LINE A CH. A I/O PHONE LINE A CH. A I/O PHONE LINE A CH. A I/O PHONE LINE A CH.
CH.A Marix CH.A I/O CH.B Matrix CH.B I/O CH.A Marix CH.A I/O CH.B Matrix CH.B I/O Figure 2-2: IMF-102 Interface Frame Rear Panel For more information on the IMF-102 interface frame, refer to the Interface Module Frames Instruction Manual in the Eclipse manual set (part no. 810313Z). INSTALLING THE FOR-22 IN AN INTERFACE FRAME IMF-3 INTERFACE FRAME This section describes how to install an FOR-22 unit in an IMF-3 frame.
• Microphone level ----------------- -55.0 dBu at 20 ohms To set channel 1 for the desired level: 1. Find jumper block JP100 on the circuit board. 2. Move the jumper so that it connects the pair of jumper pins labeled with the desired level (Line, IFB, or Mic). To set channel 2, repeat the above procedure using JP200. Each FOR-22 channel can also be adjusted using its "Send" front panel control. See Figure 3-1 in Chapter 3 for a diagram of the FOR-22 main PCB showing the location of the jumpers.
WIRING The FOR-22 interface connects to an Eclipse matrix through the two RJ-45 connectors on the IMF-3 or IMF-102 rear-panel assembly to which the FOR-22 unit is connected. One RJ-45 connector is for the first channel of the interface. The second RJ-45 connector is for the second channel. Figure 2-3 shows pin assignments of the RJ-45 connectors used to connect the interface to an Eclipse matrix.
FOR-22 I/O DB-9M 1 Audio Output Audio Output 6 2 Audio Input Audio Input 7 3 Logic Input (+/- 4 to 50 V) Logic Input (+/- 4 to 50 V) 8 4 Relay Normally Closed Relay Wiper 9 5 Relay Normally Open Figure 2-4: Pinout of the DB-9M I/O Connectors for FOR-22s EXTERNAL AUDIO DEVICES Connect external audio devices to the FOR-22 ports through the two DB-9M connectors labeled "I/O" on the rear panel assembly panel. Both audio input and output are transformer isolated. Refer to Figure 2-4 for pinouts.
ADJUSTMENTS After installation the front-panel controls should be set to accommodate the normal range of input and output levels encountered. The following is a discussion of the controls and indicators on the front of the interface. "Send Level" Control The "send level" control allows adjustment of the output level of the channel from the matrix to the external device/system.
2-8 Vitec Group Communications FOR-22 Dual 4-Wire Interface Instruction Manual
3 MAINTENANCE This chapter provides schematics, assembly drawings, and component lists for the FOR-22 dual 4-wire interface module. FOR-22 MAIN PCB Figure 3-1: FOR-22 Main Board PCB (Part No.
BILL OF MATERIALS FOR FOR-22 MODULE PCB Designator C103,C105,C107,C110,C115, C119,C203,C205,C207,C210, C215,C219 C104,C106,C111,C114,C117, C118,C204,C206,C211,C214, C217,C218 C101,C102,C109,C201,C202, C209 C113,C112 J1 JP100,JP200 J2 JP200,JP100 P101,P102,P201,P202 J1(2) LED101,LED201 R110,R122,R123,R210 R118,R119,R218,R219 R125,R225 R115,R215 R229,R129 R109,R209 R130,R230 R208,R108 R120,R121,R124,R220,R221, R224 R105,R106,R114,R116,R117, R126,R127,R131,R132,R205, R206,R214,R216,R217,R226, R227,R231,R232 R1
C202 .22 uF 1 2 1 C201 .22 uF 1 2 FROM MATRIX CHANNEL B C102 .22 uF 1 2 1 C101 .22 uF 1 2 FROM MATRIX CHANNEL A R101 27.4K R201 27.4K R202 27.4K 1 R102 27.4K 1 2 2 2 1 2 R103 27.4K R203 27.4K C204 .1 uF 2 C104 .1 uF 8 C203 33 pF 3 + -8V 1 +8V -8V 2 - C103 33 pF 3 + 2 - 1 +8V 2 2 IC201A LM833 1 R204 27.4K C205 33 pF 1 2 IC101A LM833 1 R104 27.4K C105 33 pF 1 2 1 1 C206 .1 uF R205 10.0K CW CCW SEND C106 .1 uF R105 10.
ASSEMBLY DRAWING FOR FOR-22 LEVEL DETECT PCB Figure 3-3: Assembly Drawing for FOR-22 Level Detect PCB (Part No.
BILL OF MATERIALS FOR FOR-22 LEVEL DETECT PCB Designator C5,C6,C7,C8 C4,C2 C1,C3 P1 LED2,LED1 R9,R8 R2,R5 R1,R4,R7 R3,R6 VR2,VR1 IC1 D1,D2,D3,D4,D5,D6,D7,D8 IC2,IC3 Vitec Group Communications FOR-22 Dual 4-Wire Interface Instruction Manual Component Description .1UF 50V 10% X7R SMD 0805 .22UF 50V 10% X7R SMD 1210 .47UF TAN 35V 10% SMT A FOR-22 LED SMT PCB FAB DUAL ROW HEADER 7 POS. .320IN BI-COLOR RED/GREEN 3 LEAD 475 1/10W 1% SMD 0805 23.7K 1/10W 1% SMD 0805 47.
1 3 5 7 9 11 13 + + + + + + + P1 + + + + + + + 2 4 6 8 10 12 14 C3 .47uF R1 47.5K R4 47.5K C1 .47uF 1 2 + 6 5 THRESHOLD VR2 100K 3 1 + 3 7 IC1A LM833 1 R2 23.7K 1 3 2 D2 BAV99 2 D4 BAV99 D3 BAV99 3 C6 .1uF 1 C5 .1uF 3 C4 .22uF C2 .22uF R6 332K R3 332K BAV99 D6 D5 BAV99 3 3 + 2 3 + 6 5 + 2 3 + 6 5 1 IC3B LM358 7 IC3A LM358 1 IC2B LM358 7 IC2A LM358 1 3 D7 BAV99 D8 BAV99 C8 .1uF 1 C7 .
4 SPECIFICATIONS Note: 0 dBu is Referenced to 0.
Operating Environment Temperature Between 0ºC and 70°C (32ºF -150°F) Package Dimensions Frame Slot Usage Weight 1 slot of IMF-3 or IMF-102 frame 0.54 lb (0.22 kg) Notice About Specifications While Vitec Group Communications makes every attempt to maintain the accuracy of the information contained in its product manuals, that information is subject to change without notice.
LIMITED WARRANTY Vitec Group Communications (VGC) warrants that at the time of purchase, the equipment supplied complies with any specification in the order confirmation when used under normal conditions, and is free from defects in workmanship and materials during the warranty period.
Telephone for Europe, Middle East and Africa: +49 40 6688 4040 or +44 1223 815000 Telephone for the Americas and Asia: +1 510 337 6600 Email: vitec.support@AVC.de Once the standard warranty period has expired, the User Support Center will continue to provide telephone support if you have purchased an Extended Warranty. For latest contact information please refer to the Service and Support section at www.clearcom.com.
purchase of an extended warranty extends to five years the warranty of any product offered with a standard two-year warranty. The total warranty period will not extend beyond five years. Note: VGC does not offer warranty extensions on UHF wireless intercom systems, or on any product with a 1-year or 90-day warranty. LIABILITY THE FOREGOING WARRANTY IS VGC'S SOLE AND EXCLUSIVE WARRANTY.