Products Owner's manual

32 • Chassis and Blade Installation R-Series Data Center Products User’s Guide
Power Modules
The R4300 contains two Power Supply Units (PSUs) and a Dual Input Module (DIM).
With the redundancy provided by two PSUs and two power inputs, the R4300 will
stay running even if one PSU fails, or a power input fails, or if a PSU and a power
input fail together.
DHCP
Bi-color LED indicates IP address assignment mode
Green = DHCP
Off = fixed IP address
DC POWER
Bi-color LED indicates power supply status
Green = 2 supplies good
Red = 1 supply bad
Off = no power or RMM not seated properly
HEALTH
Bi-color LED indicates system health
Green = good
Amber = RMM firmware update in progress
Red = bad
Off = no power or RMM not seated properly
See the Sentral Administrator’s Guide for more information on RMM Status indicators
LINK
Bi-color LEDs that indicate Ethernet link speed
Green = 100 Mb/sec.
Amber = 10 Mb/sec.
ACTIVITY
Green LED – flashing indicates activity
Table 7 R4300 Network Module Features: Models 4362 (EP2) and 4363 (EP6)
Connectors
PRI/SEC Blue
Blue LED that
, when lit,
indicates that the Status LEDs
above the Management Bay
module
are displaying status for the Primary or Secondary Ethernet connections.
ETHERNET
RJ45 connections that provide Ethernet connections for each PC blade in the chassis.
Label numbers correspond to the blade slot numbers on the front of the chassis.
R4363 (EP2)—GB Primary ports (right side) and GB Secondary ports (left side)
R4362 (EP6)—GB Primary ports (right side) and 10/100 Secondary ports (left side)
Primary Ethernet Secondary Ethernet