Instruction Manual

218 Technical Services: 800-283-5936
DEVICETYPE – Sets the Type of a Connected Device
This command enables / disables or reports the current type of device connected to an input or output.
Command Form: DEVICE DEVICETYPE <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 1, 2, 3, 7 (I, O, M, L)
Value Unsigned Integer 2 (NULL to query in text)
DFLTM – Default Meter
This command selects/reports the setting of the default meter on the front panel.
Command Form: DEVICE DFLTM [Channel Group Position]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
(Null to query in text)
Group Group 1 1, 2, 3, 7, 16, 17 (I, O, M, L, T, R)
Position Meter Type
2 1 – 4, as applicable for group
See Meter Type Definitions
DIAL – DTMF Dialing
This command dials a DTMF sequence or reports back the last sequence dialed.
Command Form: DEVICE DIAL <Channel> [Number]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 17 (R)
Reserved
2 0
Number
String 40 1 – 40 Chars of ‘0’ – ‘9’, ‘A’ – ‘D’, ‘*’, ‘#’, ‘,’
(Null to query last number dialed in text)
DID – Device ID
This command reports the device id. This command is read only except through the front panel.
Command Form: DEVICE DID [Value]
Argument Type Size Values Units
Value Unsigned Integer 4 See Type And Device IDs
(Null sent in text, Value returned)
DSPVER – DSP Version
This command reports the version of the DSP code in the unit. This command is read only.
Command Form: DEVICE DSPVER <Value> [Time/Date]
Argument Type Size Values Units
Value Unsigned Integer 4 0 for Host
1 – 8 for Satellite
9 for Telco
Time / Date
String 16 (Null to query in text)