Instruction Manual

224 Technical Services: 800-283-5936
GOVER – Gating Override
This command selects/reports the setting of gating override.
Command Form: DEVICE GOVER <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 3 (M)
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
GPIOSTATUS – General Purpose Status
This command sets the state of a General Purpose Status Pin.
Command Form: DEVICE GPIOSTATUS Pin Port [Value]
Argument Type Size Values Units
Pin Unsigned
Integer
1 1 – 24 (Only user definable status pins.
Port Unsigned
Integer
1 1 – 2
Value Unsigned
Integer
2 0 = High
1 = Low
2 = Toggle
(NULL to query in text)
GRATIO – Gate Ratio Adjust
This command selects/reports the setting of the gate ratio.
Command Form: DEVICE GRATIO <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 3 (M)
Value Unsigned Integer 2 0 – 50
(Null to query in text)
dB
GREPORT – Gate Report
This command selects/reports the mode of gate and audio presence status reporting.
Command Form: DEVICE GREPORT [Value]
Argument Type Size Values Units
Value Unsigned Integer 4 0 = Off
1 = On
2 = Toggle
(Null to query in text)