Instruction Manual

228 Technical Services: 800-283-5936
LOGMASK – Device Log Mask
This command sets or reports the device event log mask.
Command Form: DEVICE LOGMASK [Value]
Argument Type Size Values Units
Value Hexadecimal 4 X X X X X X X X X X X X X X X X
| | | | | | | | | | | | | | | | Reset
| | | | | | | | | | | | | | | Errors
| | | | | | | | | | | | | | Password Access
| | | | | | | | | | | | | Telco On/Off
| | | | | | | | | | | | Dial
| | | | | | | | | | | Call Duration
| | | | | | | | | | System Checks
| | | | | | | | | (reserved)
| | | | | | | | (reserved)
| | | | | | | Default
(Null to query in text)
LVL – Level
This command reports the level of a channel. This command is read only.
Command Form: DEVICE LVL <Channel> <Group> <Position> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 1, 2, 3, 5, 7, 12, 16, 17, 20
(I, O, M, P, L, F, T, R, B)
Position Meter Type
2 See Meter Type Definitions
Value Signed Float 4 -99.99 – 99.99
(Sent with Null in text, Value returned)
dB
LVLREPORT – Level Report
This command selects/reports the status of level reporting for the specified channel.
Command Form: DEVICE LVLREPORT <Channel> <Group> <Position> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 1, 2, 3, 5, 7, 12, 16, 17
(I, O, M, P, L, F, T, R)
Position Meter Type
2 See Meter Type Definitions
Value Unsigned Integer 4 0 = Off (Delete from list being reported)
1 = On (Add to list being reported)
2 = Toggle
(Null to query in text)
LVLREPORTEN – Level Report Enable
Enables level reporting for the unit.
Command Form: DEVICE LVLREPORTEN [Value]
Argument Type Size Values Units
Value Unsigned Integer 4 0 = Turn off reporting but leave current list
1 = Turn on reporting
2 = Turn off reporting and clear the list
(Null to query in text)