Instruction Manual

Appendix A: Serial Commands 237
Group Group 1 20 (B)
Value Reference Output 2 0 = none
See 2 (O) in Groups and Channels
(Null to query in text)
RESET – Reset
Resets the unit. There is no query for this command.
Command Form: DEVICE RESET
No Arguments
RING – Ring Indication
This command indicates a ringing line. This command is reportable only. It cannot be queried or set.
Command Form: DEVICE RING <Channel><Value>
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 17 (R)
Value Unsigned
Integer
2 0 = Ring Cycle Ended
1 = Ring Cycle Started
RINGEREN – Audible Ring Enable
This command sends/reports the use of an audible ring.
Command Form: DEVICE RINGEREN <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 17 (R)
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
RINGERLVL – Audible Ring Level
This command selects/reports the audible ring’s level.
Command Form: DEVICE RINGERLVL <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 17 (R)
Value Signed Float 2 -12.00 – 12.00 (dB)
(Null to query in text)
RINGERSEL – Audible Ring Melody Selection
This command sends/reports the audible ring melody.
Command Form: DEVICE RINGERSEL <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 17 (R)
Value Unsigned Integer 2 1 – 3
(Null to query in text)