Instruction Manual

244 Technical Services: 800-283-5936
UID – Unit ID
This command reports the unit id. This command is read only.
Command Form: DEVICE UID [Value]
Argument Type Size Values Units
Value Hexadecimal 4 (Sent with a Null, value returned in text)
VER - Version
This command reports the version of the unit. This command is read only.
Command Form: DEVICE VER [Value]
Argument Type Size Values Units
Value String 8 Version of format MM.mm.rr
(Sent with a Null in text, value returned)
WAITSTATE – Wait State
This command defines a delay within macros and presets in ½ second increments from ½ second to 5
seconds. This command can only be included in a macro. It will be ignored from other sources.
Command Form: DEVICE WAITSTATE <Value>
Argument Type Size
Values
Units
Value Unsigned Float 1 0.50 – 5.00 S