Specifications
21 www.clearone.com
Mixing Parameters
Parameter Range Description
Microphone Activation
Auto gate, manual
gate, on/off
Sets the method of microphone gating.
Chairman Override
On/off
When a chairman override channel is
gated on, all non-chairman inputs are
gated off.
Adaptive Ambient mode
On/off Automatically sets the ambient audio
level of the room averaged over time.
PA Adaptive mode
On/off This prevents mic channels from gating
on to loudspeaker audio.
Maximum number of
mics on
1–8 or off
Sets the maximum number of
microphones allowed to be gated on at
a time.
First Mic Priority mode
On/off
Increases the audio level required to gate
on additional microphones after the first
mic is gated on.
Last Mic mode
Last, Mic 1–8, Off
Keeps the last gated microphone or one
Mic 1–8 on when no mics are providing a
gating input.
Gate Ratio Adjust
0 to 50dB
Specifies how much louder above the
ambient level the audio level must be to
gate on.
Off Attenuation Adjust
0 to 50dB Sets how much the microphone will be
attenuated when it is not gated.
Hold Time
.1 to 8.0 seconds
Programs the amount of time it takes
until the mic starts the off attenuation
process.
Decay Rate
Slow, medium, fast
Programs how quickly the audio level is
attenuated once an input hold time has
expired.
Manual Ambient Level
0 to -80dB Sets the ambient audio level when the
adaptive ambient mode is off.
NOM/Constant Gain
mode
On/off
Maintains constant gain of a selected
output. As more mics gate on, each mic
is appropriately attenuated.
Figure 5.5