Specifications

98 Chapter 3: ConvergeĀ® Console Programming
Min/Max Limits
Use the yellow and green upper and lower limit arrows on the Gain Scale in the Gain section of the screen to set
minimum and maximum gain level limits. These limits only apply when using relative gain commands; absolute gain
commands can exceed the min and max limits. Min/Max limits apply to all serially connected control devices and
prevent users from adjusting levels beyond the min/max levels.
Post-Gain Meter
The Post Gain level meter displays the post-gain signal level in dB.
Limiter Meter
The Limiter limits the output level to the telco side to comply with FCC requirements.
Output Level Meter
Shows the signal level in dB when a signal is present. Range is from -30 to +20dB.
Channel Routing Matrix
The graphic below shows the Telco TX channel routing matrix.
All inputs from Exp. O, and from Exp. S are selected as cross points and the first four inputs are gated by default.
Clicking a cross point box selects it, clicking it a second time sets the cross point, as indicated by a green box. The
dB level for set cross points is shown numerically in the box.