Specifications
Technical Services: 800-283-5936 209
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
CLOCK – CLOCK SET
This command sets or reports the current time.
Command Form: DEVICE CLOCK [Date Month Year Hours Minutes Seconds Day]
Argument Details
Name Type Size Values Units
Date Unsigned Integer 1 1 – 31
Month Unsigned Integer 1 1 – 12
Year Unsigned Integer 2 2000 – 2099
(NULL to Query in Text)
Hours Unsigned Integer 1 00 – 23
Minutes Unsigned Integer 1 00 – 59
Seconds Unsigned Integer 1 00 – 59
Day of Week Unsigned Integer 1 1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
COMPRESS - COMPRESSOR ADJUST
This command selects/reports the settings of the compressor.
Command Form: DEVICE COMPRESS <Channel> [Threshold Ratio Attack Release Gain]
Argument Details
Name Type Size Values Units
Channel Channel 1 See Group and Channels
Group Group 1 5 (P)
Threshold Signed Integer 1 -60 – 20
(Null to query in text)
dB
Ratio Unsigned Integer 1 1 – 20
Attack Unsigned Float 2 0.00 – 100.00 Ms
Release Unsigned Integer 2 100 – 2000 Ms
Gain Unsigned Float 4 0.00 – 20.00 dB
COMPSEL - COMPRESSION SELECT
This command selects/reports the compressor activation.
Command Form: DEVICE COMPSEL <Channel> [Value]
Argument Details
Name Type Size Values Units
Channel Channel 1 See Group and Channels
Group Group 1 5 (P)
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
COUNTRY – COUNTRY SELECTION
This command sets / reports the country for compliance.
Command Form: DEVICE COUNTRY [Value]
Argument Details
Name Type Size Values Units