Specifications

Technical Services: 800-283-5936 231
RESET - RESET
Resets the unit. There is no query for this command.
Command Form: DEVICE RESET
Argument Details
None
RING - RING INDICATION
This command indicates a ringing line. This command is reportable only. It cannot be queried or set.
Command Form: DEVICE RING <Channel><Value>
Argument Details
Name Type Size Values Units
Channel Channel 1 See Group and Channels
Group Group 1 17 (R)
Value Unsigned
Integer
2 0 = Ring Cycle Ended
1 = Ring Cycle Started
RINGEREN - AUDIBLE RING ENABLE
This command sends/reports the use of an audible ring.
Command Form: DEVICE RINGEREN <Channel> [Value]
Argument Details
Name Type Size Values Units
Channel Channel 1 See Group and Channels
Group Group 1 17 (R)
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
RINGERLVL - AUDIBLE RING LEVEL
This command selects/reports the audible ring’s level.
Command Form: DEVICE RINGERLVL <Channel> [Value]
Argument Details
Name Type Size Values Units
Channel Channel 1 See Group and
Channels
Group Group 1 17 (R)
Value Signed Float 2 -12.00 – 12.00 (dB)
(Null to query in text)
RINGERSEL - AUDIBLE RING MELODY SELECTION
This command sends/reports the audible ring melody.
Command Form: DEVICE RINGERSEL <Channel> [Value]
Argument Details
Name Type Size Values Units
Channel Channel 1 See Group and Channels
Group Group 1 17 (R)
Value Unsigned Integer 2 1 – 3
(Null to query in text)
RINGERTEST - AUDIBLE RING MELODY TEST
This command plays the current audible ringer melody. This command is executable only. There is no query.