Specifications
Technical Services: 800-283-5936 233
SFTYMUTE – SAFETY MUTE
This command selects/reports the state of the safety mute. When on, the safety mute holds all outputs in a muted
state. It used for syncing to a G-Ware document to avoid feedback or blown speakers until the box is in a settled
state.
Command Form: DEVICE SFTYMUTE [Value]
Argument Details
Name Type Size Values Units
Value Channel 4 0 = off
1 = on
2 = toggle
(Null to Query in Text)
SIGGEN - SIGNAL GENERATOR
This command selects/reports of the signal generator activation.
Command Form: DEVICE SIGGEN [Channel Group Type Amplitude Frequency]
Argument Details
Name Type Size Values Units
Channel Channel 1 See Group and Channels
(Null to query in text)
Group Group 1 1, 3, 7 (I, M, L)
Type Unsigned Integer 2 1 = Pink Noise
2 = White Noise
3 = Tone
Amplitude Signed Float 4 -60.00 – 20.00 DB
Frequency Unsigned Float 4 Type 1 – 2 0 (Null in text) Hz
Type 3 20.00 – 20000.00
SIGGENEN - SIGNAL GENERATOR ENABLE
This command selects/reports of the signal generator activation.
Command Form: DEVICE SIGGENEN [Value]
Argument Details
Name Type Size Values Units
Value Unsigned Integer 4 0 = Off
1 = On
2 = Toggle
(Null to Query in Text)
SIGGENSWEEP - SIGNAL GENERATOR SWEEP
This command starts the signal generator with a tone and does a sweep. If repeat is 0, the signal generator will turn
off after the sweep. If repeat is 1, the signal generator will turn off after signal generator timeout. To stop the sweep,
send a SIGGENEN command with a 0. During the sweep, the box will send out updated SIGGEN commands.
Command Form:
DEVICE SIGGENSWEEP <Channel> <Group> <Amplitude> <Start Frequency> <End Frequency>
<Increment Frequency> <Rate> <Repeat>
Argument Details
Name Type Size Values Units
Channel Channel 1 See Group and Channels
Group Group 1 1, 3, 7 (I, M, L)
Amplitude Signed Float 2 -60.00 – 20.00 DB