Specifications

234 Appendix A: Serial Commands
Start
Frequency
Unsigned Float 4 20.00 – 20000.00 Hz
End
Frequency
Unsigned Float 4 20.00 – 20000.00 (must be greater
than the start)
Hz
Increment
Frequency
Unsigned Float 4 1.00 – 20000.00 Hz
Rate Unsigned Integer 2 10 – 2000 ms Hz
Repeat Unsigned Integer 2 0 = repeat off
1 = repeat on
SIGTOUT - SIGNAL GENERATOR TIME OUT
Sets the signal generator time out for the unit.
Command Form: DEVICE SIGTOUT [Value]
Argument Details
Name Type Size Values Units
Value Unsigned Integer 4 0 = Disable
1 – 30
(Null to query in text)
Min
SLVL - SPEECH LEVEL CONTROL
This command selects/reports the setting of Speech Level Control.
Command Form: DEVICE SLVL <Channel> [Value]
Argument Details
Name Type Size Values Units
Channel Channel 1 See Group and Channels
Group Group 1 3 (M)
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
SMTPSRV – SMTP MAIL SERVER ADDRESS
This command selects/reports the IP address of the SMTP Mail server, and the Email Address the unit’s SMTP client
sends messages to.
Command Form: DEVICE SMTPSRV [Value Address]
Argument Details
Name Type Size Values Units
Value IP Address 4 (Null to query in text)
(0.0.0.0 Clears IP and String)
Address String 40 1 – 116 characters
(Null to query in text)
SNMPMNGRIP – SNMP MANAGER HOST IP ADDRESS
This command selects/reports the IP address of the SNMP Manager.
Command Form: DEVICE SNMPMNGRIP [Value]
Argument Details
Name Type Size Values Units
Value IP Address 4 IP Address of SNMP Manager to send Traps to
(Null to query in text)