Specifications

26 Chapter 2: Expansion Bus & LCD Programming
These options are described in the following sections.
RS-232
There are two parameters in the RS-232 menu: Baud Rate and Flow Control. To change these settings, use the
following procedure
Use the Menu Dial to highlight Baud Rate or Flow Control
Press the Select button
Select the desired value using the Menu Dial
Press the Select button to set the selected value
Press the Esc button to return to the Settings menu
You can also use the Comm tab of the Unit Properties screen in Console to change these settings.
Baud Rate
This parameter allows you to set the baud rate to 9.6kbps, 19.2kbps, 38.4kbps, or 57.6kbps. Default is 57.6 kbps.
Select the baud rate you want to use, then press the Select button. A message appears on the LCD display
indicating the change is in progress, and another indicating the change is complete. When finished, the display
returns to the RS-232 sub-menu.
Flow Control (Hardware)
Converge Pro devices use the RTS and CTS pins on the RS-232 port to regulate the transmission and reception
of data. You can enable or disable flow control on the front panel of unit and select the flow control type in the Site
Properties window of Console.
If you select On (default) from the front panel LCD menu, select Hardware as the flow control type in the Site
Properties window. If you disable flow control on the front panel, select None in the Site Properties window. When
None is selected, Converge Pro units ignore flow control, and the connected external control device ensures that
data is not lost. All Converge Pro devices support software flow control (Xon/Xoff), but you should only use it with a
pass-through external device such as a modem.
NOTE: ClearOne recommends that you leave Flow Control enabled. To avoid communication
errors, ClearOne strongly recommends that you connect all DB9 pins and enable flow
control when connecting to a PC.
Network
The Network submenu displays the unit name, DID (Device ID), IP address, Gateway, and Subnet Mask settings
for the Converge Pro unit. You cannot change any of these settings from the Network submenu. Use the Unit
Properties screen in the Console software to change these settings.
DID
The DID submenu allows you to select a Device ID for the Converge Pro unit. Select the DID you want to use, press
the Select button. Answer Yes to the prompt to change the DID, or No to keep the existing setting.
You can also use the Comm tab of the Unit Properties screen in Console to change this setting.
Default
Default restores ALL settings to their factory default values. Answer Yes to the prompt to restore default settings, or
No to retain the existing custom settings.
Contrast
Contrast allows you to change the LCD contrast level. Use the Menu Dial to adjust the contrast level, then press
the Select button to save it.