Specifications
78 Chapter 3: ConvergeĀ® Console Programming
Pre Gain Meter
The Pre Gain Meter shows the line input level before gain adjustments. Meter range is -30 to 20dB.
NOTE: All meters in Console are peak-level meters.
Gain Slider
The Gain Slider adjusts the line input volume level. Range is from -65dB to +20dB.
Post Gain Meter
The Post Gain Meter shows the input level after gain adjustments. Meter range is -30 to +20dB.
Mute Button
Clicking the Mute button toggles muting. The default is off.
AGC (Automatic Gain Control) Button
Clicking the AGC (Automatic Gain Control) button displays the Channel Property Configuration dialog for the
selected input channel as shown below.