Specifications
Technical Services: 800-283-5936 89
The Cross Point Attenuation slider appears. Move the slider or use the selector box to set the gain/attenuation
level in dB. The range is from -60 to 12dB in .5dB increments. The default is 0dB.
NOTE: Your changes are automatically saved when you close the slider.
In the channel routing matrix, pressing the button underneath an Output, Process, or Fader cross-point box
displays the signal flow diagram and configuration controls for that output channel as shown below.
This display is identical to that shown in Channel View when the output channel is selected in the Tree View pane.
See Output Settings for more information.
You can change the label (name) of the output channel in the Output entry box, toggle the NOM button to turn
constant gain mode on or off, toggle the Mute button to mute or un-mute the channel, and use the Gain slider to
set the gain level for the channel. The Output Level meter shows the level for the channel in real time.
NOTE: Changes to configuration settings made in the channel routing matrix apply globally to
the output, processing, or fader channel. For example, changing the label (name) from
“Output 1” to “Ceiling Speakers” changes the name of the output channel in the Tree View
pane, and everywhere else the label appears in Console.
Creating Channel Objects
One of the most powerful features of the Console software is the ability to create Audio Devices and Channel
Objects. After configuring the telco rx channel using the Channel View tab as described in this topic, you can save
it into the Database, and use Drag and Drop Configuration to streamline configuration tasks for your
Converge Pro installations.