Operation Manual

278
Value Unsigned Short 2 0 = 100
1 = 150
2 = 200
3 = 256
4 = 384
5 = 512
6 = 640
7 = 1024
(Null to query in text)
ms
RXBOOST – Receive Boost
This command selects/reports the receive boost status.
Command Form: DEVICE RXBOOST <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 17 (R)
Value Unsigned Integer 2 0, 3, 6, 9, or 12
(Null to query in text)
dB
RXBSTEN – Receive Boost Enable
This command selects/reports the receive boost status.
Command Form: DEVICE RXBSTEN <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 17 (R)
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
SERECHO – Serial Echo
This command selects/reports the serial echo of the RS-232 port.
Command Form: DEVICE SERECHO [Value]
Argument Type Size Values Units
Value Unsigned Integer 4 0 = Off
1 = On
2 = Toggle
(Null to query in text)
NOTE: The unit will return the updated state of the last selection in the same form as the
command.
SFTYMUTE – Safety Mute
This command selects/reports the state of the safety mute. Safety mute holds all outputs in a muted state. It used
for syncing to a site document to avoid feedback or blown speakers until the unit is in a settled state.
Command Form: DEVICE SFTYMUTE [Value]
Argument Type Size Values Units
Value Channel 4 0 = off
1 = on
2 = toggle
(Null to query in text)