Operation Manual

254
Node Unsigned Integer 1 Group 3 1 – 4
0xFF for all (*
text)
Group 5 1 – 15
0xFF for all (*
text)
Value Unsigned Integer 1 0 = Off
1 = On
2 = Toggle
(Null to query in text)
FLOW – Flow Control
This command selects/reports the flow control of the serial port on the unit. Hardware flow control is implemented
using DTR and DSR.
Command Form: DEVICE FLOW [Value]
Argument Type Size Values Units
Value Unsigned Integer 4 0 = Off
1 = On
2 = Toggle
(Null to query in text)
FMP – First Mic Priority Mode
This command selects/reports first Mic priority mode.
Command Form: DEVICE FMP <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 4 (G)
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
GAIN – Gain Adjustment
This command changes or reports back the gain for a channel.
Command Form: DEVICE GAIN <Channel> <Group> [Value] [Absol/Rel]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 1, 2, 3, 5, 7, 12, 16, 17, 25, 26 (I, J, O, M, P, L, F, T, R, K, Z)
Value Signed
Float
2 -99.90 – 99.90 **
(Null to query in text)
dB
Absol / Rel 0 A = Absolute
R = Relative
Null = Relative
NOTE: Values indicate valid range for entry values only. Actual internal range of the gain stage is
from –65 to 20. Absolute values will be limited to the internal gain range.
GATE – Gate Status
This command reports the gate status of Mics. This command is read only.
Command Form: DEVICE GATE [Value]
Argument Type Size Values Units
Value Hexadecimal 4 Bits 0 – 7 represent gate status on Mics 1 – 8
(Null sent in text, Value returned)