TE – Telco Enable
This command selects/reports the hook status.
Command Form: DEVICE TE <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 17 (R)
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
TELCOLVLCTRL – Telco RX Level Control Enable / Disable
This command selects/reports the setting of Telco Rx level control.
Command Form: DEVICE TELCOLVLCTRL <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 17 (T)
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
TELOVER – Telco Current Overload
This command reports that the Telco circuitry has experienced a current overload that has forced it to go off hook.
This condition can occur because of a connection to a Digital PBX, and is done to protect the Telco Circuitry from
damage. The command is a notification only, and cannot be set or queried.
Command Form: DEVICE TELOVER <Channel><Overload>
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 17 (R)
Value Unsigned Short 2 0 = Not Overloaded
1 = OVERLOADED
TIMELOCALE – Time Locale Settings
This command sets or reports the time locale settings.
Command Form: DEVICE TIMELOCALE [DaylightSavings TimeZone TimeZoneName]
Argument Type Size Values Units
Daylight Savings Unsigned Integer 4 0 = Do not use Daylight Savings
1 = Use Daylight Savings
(NULL to Query in Text)
Time Zone Unsigned Integer 4 The number of seconds from UDT. (-86400
– 86400)
Time Zone
Argument
String 32 Description of time zone