Operation Manual

284
TOUT – Time Out Select
This command selects/reports the inactivity time out before returning to the unit title screen on the front panel.
Command Form: DEVICE TOUT [Value]
Argument Type Size Values Units
Value Unsigned Integer 4 0 = No Time Out
1 – 15
(Null to query in text)
Min
UID – Unit ID
This command reports the unit id. This command is read only.
Command Form: DEVICE UID [Value]
Argument Type Size Values Units
Value Hexadecimal 4 (Sent with a Null, value returned in text)
VER - Version
This command reports the version of the unit. This command is read only.
Command Form: DEVICE VER [Value]
Argument Type Size Values Units
Value String 8 Version of format MM.mm.rr
(Sent with a Null in text, value returned)
XAA – Auto Answer Enable/Disable
This command selects/reports the setting of auto answer. This command can be used to replace the AA
command for the R group.
Command Form: DEVICE XAA <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 17, 26 (R, Z)
Value Unsigned Short 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
XAARINGS – Number of Rings to Auto Answer On
This command selects/reports the setting of the number of rings to auto answer. This command can be used to
replace the AARINGS command for the R group.
Command Form: DEVICE XAARINGS <Channel> <Group> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 17, 26 (R, Z)
Value Unsigned Short 2 2-4
(Null to query in text)